Positions and Functions of Specification Selector Switches
SW3-1 Manual Reset Selector Switch
SW1 Time Range Selector Switch
SW1
Switch position
Rated time
0
99.99 s
1
999.9 s
2
9999 s
3
99 min 59 s
4
999.9 min
5
99 hrs 59 min
6
999.9 hrs
7
9999 hrs
8
99.99 s
9
999.9 s
Note: Select the appropriate label, from the rated time labels sup-
plied as accessories, and affix it on the proper position on
the front panel.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Enable
Disable
Setting range
0.01 to 99.99 s
0.1 to 999.9 s
1 to 9999 s
1 s to 99 min 59 s
0.1 to 999.9 min
1 min to 99 hrs 59 min
0.1 to 999.9 hrs
1 to 9999 hrs
Same as switch
position "0"
Same as switch
position "1"
Two mounting fixtures
M3.5 terminal screws
67.6 x 67.6
SW3-2 Solid-state Output Level Selector Switch
H: (Output level changes "low" to "high" when
the set time is up.)
L: (Output level changes "high" to "low" when
the set time is up.)
SW2 Operation Mode Selector Switch
SW2
Switch position
Operating mode
0
N
1
F
2
C
3
R
4
K
5
P
6
Q
7
N (see note 1)
8
N
9
F
A
C
B
R
C
K
D
P
E
Q
F
N (see note 2)
Panel Cutouts
(Panel cutout conforms
to DIN 43700)
H5AN
Display mode
DOWN display
Note: 1. Same
as
it h
switch
position "0"
position "0"
UP display
Note: 2. Same
as
switch
it h
position "8"
position "8"
(Horizontally connecting
N units)
{(n – 1) x 72 + 70 } min.
(including 2-mm clear-
ance between units)
N