Important Safety Information; Appliance Certification; Btu & Efficiency Specifications - Quadra-Fire 3100 MILLENNIUM Installation Manual

Wood appliance automatic combustion control
Hide thumbs Also See for 3100 MILLENNIUM:
Table of Contents

Advertisement

1

Important Safety Information

A. Appliance Certification
Model: 3100 Millennium Wood Appliance
Laboratory: OMNI Test Laboratories, Inc.
Report No: 0061WS066S
Listed Room Appliance, Solid
Type:
Fuel Type
UL1482-11 (R2015) and ULC
Standard:
S627-00 and (UM) 84-HUD, Mobile
Home Approved.
This wood appliance needs periodic inspection and repair for proper operation. Consult the owner's manual for further
information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner's manual.
NOTE: This installation must conform with local codes. In the absence of local codes you must comply with (UM) 84-
HUD and NFPA211 in the U.S.A. and CAN/CSA-B365 Installation Codes in Canada.
September 9, 2019
This 3100 Millennium is
Certified to comply with
2020 crib wood particulate
emission standards.
7033-350E
B. BTU & Efficiency Specifications
EPA Certification
Number:
EPA Certified Emissions: 1.9 grams per hour
*LHV Tested Efficiency: 78.3%
**HHV Tested Efficiency: 72.5%
***EPA BTU Output: 13,900 to 29,100 / hr
****Peak BTU/Hour
Output:
Vent Size: 6 inches
Firebox Size: 2 cubic feet
Recommended Log
Length:
Fuel
*Weighted average LHV (Low Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests. LHV assumes the moisture
is already in a vapor state so there is no loss in energy
to vaporize.
**Weighted average HHV (High Heating Value) efficiency
using Douglas Fir dimensional lumber and data collected
during EPA emission tests. HHV includes the energy
required to vaporize the water in the fuel.
***A range of BTU outputs calculated using HHV
Efficiency and the burn rates from the EPA tests, using
Douglas Fir dimensional lumber.
****A peak BTU out of the appliance calculated using
the maximum first hour burn rate from the High EPA Test
and BTU content of seasoned cordwood (8600) times
the efficiency.
31M-ACC-C
86-17
51,000
16 inches
Seasoned Cord Wood
(20% moisture)
3

Advertisement

Table of Contents
loading

Table of Contents