Download Print this page

Giant P200A-5100 Series Operating Instructions/ Repair And Service Manual page 9

Triplex ceramic plunger pump
Hide thumbs Also See for P200A-5100 Series:

Advertisement

1750 RPM *
Ratings ...................................................... 1.1 GPM @ 2000 PSI .....(4.1 LPM @ 140 bar)
3450 RPM *
Ratings ...................................................... 2.1 GPM @ 2000 PSI .....(8.1 LPM @ 140 bar)
Inlet Pressure ............................................ 14 to 145 PSI ..................(1 to 10 bar)
RPM ...................................................................................................Up to 3450 RPM
Plunger Diameter ...................................... 0.71" ................................18mm
Stroke ....................................................... 0.13" ................................3.4mm
Temperature of Pumped Fluids ................. Up to 86
Inlet Ports ..........................................................................................(2) 1/2" BSP
Discharge Ports .................................................................................(2) 3/8" BSP
Shaft Rotation ......................................................................................Top of Pulley Towards Fluid End
Crankshaft Diameter ..........................................................................24mm
Key Width ..........................................................................................8mm
Shaft Mounting ...................................................................................Right Side Facing Manifold
Weight ....................................................... 13 lbs. 4 oz. ....................(6.0 kg)
Crankcase Oil Capacity ............................ 8.1 fl.oz. ..........................(0.24 liter)
Volumetric Efficiency @ 1750 RPM ...................................................0.94
Volumetric Efficiency @ 3450 RPM ...................................................0.87
Mechanical Efficiency @ 3450 RPM .................................................0.86
*
Positive inlet pressure required
Consult the factory for special requirements that must be met if the
pump is to operate beyond one or more of the limits specified above.
PULLEY INFORMATION
Pulley selection and pump speed are based on a 1725
RPM motor and "B" section belts. When selecting
desired GPM, allow for a ±5% tolerance on pumps
output due to variations in pulleys, belts and motors
among manufacturers.
1.
Select GPM required, then select appropriate
motor and pump pulley from the same line.
2.
The desired pressure is achieved by selecting
the correct nozzle size that corresponds with the
pump GPM.
Specifications
Model P230A-5100
U.S.
P230A-5100
P230-5100 HORSEPOWER
REQUIREMENTS
RPM
GPM
1000 PSI 1500 PSI 2000 PSI
0.9
1450
0.6
0.8
1750
1.1
3000
1.9
3.6
3200
3.8
2.0
3450
2.1
4.0
(Metric)
o
F ......................(30
HORSEPOWER RATINGS:
The rating shown are the power require-
ments for the pump. Gas engine power
outputs must be approximately twice the
pump power requirements shown above.
We recommend a 1.15 service factor be
specified when selecting an electric motor
as the power source. To compute specific
pump horsepower requirements, use the
following formula:
GPM X PSI = HP
0.9
1.2
1.1
1.5
2.0
2.6
2.8
2.1
2.9
2.2
9
o
C)
1450

Advertisement