Download Print this page

Giant P200A-5100 Series Operating Instructions/ Repair And Service Manual page 5

Triplex ceramic plunger pump
Hide thumbs Also See for P200A-5100 Series:

Advertisement

Volume ....................................................4.2 GPM .................. (15.9 LPM)
Discharge Pressure .................................2000 PSI ................. (140 bar)
Inlet Pressure ...........................................90 PSI ..................... (6.2 bar)
RPM ........................................................................................... Up to 1750 RPM
Plunger Diameter .....................................0.71" ......................... 18mm
Stroke ......................................................0.49" ......................... 12.4mm
Temperature of Pumped Fluids ................Up to 86
Inlet Ports .................................................................................. (2) 1/2" BSP
Discharge Ports ......................................................................... (2) 3/8" BSP
Shaft Rotation ............................................................................Top of Pulley Towards Fluid End
Crankshaft Diameter ................................0.94" ......................... 24mm
Key Width ................................................0.31" ......................... 8mm
Shaft Mounting ........................................................................... Either Side
Weight ......................................................13 lbs. 4 oz. ............ (6.0 kg)
Crankcase Oil Capacity ...........................8.1 fl.oz. ................... (0.24 liters)
Volumetric Efficiency @ 1750 RPM ........................................... 0.96
Mechanical Efficiency @ 1750 RPM ......................................... 0.85
Consult the factory for special requirements that must be met if the
pump is to operate beyond one or more of the limits specified above.
PULLEY INFORMATION
Pulley selection and pump speed are based on
a 1725 RPM motor and "B" section belts. When
selecting desired GPM, allow for a ±5% tolerance
on pumps output due to variations in pulleys, belts
and motors among manufacturers.
1.
Select GPM required, then select appropriate
motor and pump pulley from the same line.
2.
The desired pressure is achieved by selecting
the correct nozzle size that corresponds with the
pump GPM.
P219A-5100 HORSEPOWER REQUIREMENTS
RPM
1150
1450
1750
Specifications
Model P219A-5100
U.S.
GPM
800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI
2.8
2.3
1.5
3.5
1.9
2.9
2.3
3.5
4.2
(Metric)
F ............... (30
o
o
C)
HORSEPOWER INFORMATION
Horsepower ratings shown are the power re-
quirements for the pump. Gas engine
power outputs must be approximately twice
the pump power requirements shown above.
We recommend that a 1.15 service factor
be specified when selecting an electric motor
as the power source. To compute specific
pump horsepower requirements, use the
following formula:
GPM X PSI
= HP
1450
2.9
3.3
3.6
4.1
4.3
4.9
5
3.9
4.8
5.8

Advertisement

loading