Mounting to DIN rail
Use a DIN rail 35 mm (1.38 in.) wide to mount the driver.
1.
Attach the DIN rail mounting plate (model number: PADP01) to the back of the driver using
the screws supplied with the plate.
DIN rail mounting plate
Mounting screws (M3)
2.
Pull the DIN lever down, engage the upper hooks of the DIN rail mounting plate over the DIN
rail, and push the DIN lever until it locks in place.
3.
Removing from DIN rail
Pull the DIN lever down until it locks using a flat blade-parallel tip type screwdriver, and lift
the bottom of the driver to remove it from the rail.
Mounting holes for the DIN rail
mounting plate (M3, three locations)
DIN rail
DIN lever
ASD24A-A
OPERATION
ALARM
CN1
1000
500
X1
X10
2P
1P
CURRENT
CN2
MOTOR
V.FIL
CN3
L
100-
115V
~
End plate
N
CN4
VEXTA
I O
/
Note
• Do not use the mounting holes
(M3, three locations) for the DIN
rail mounting plate provided in
the back of the driver for any
purpose other than securing the
DIN rail mounting plate.
• Be sure to use the supplied
screws when securing the DIN
rail mounting plate. The use of
screws that would penetrate
3 mm (0.12 in.) or more through
the surface of the driver may
cause damage to the driver.
Note
• Use force of about 10 to 20 N
(2.2 to 4.41 lb.) to pull the DIN
lever to lock it. Excessive force
may damage the DIN lever.
• Use an end plate (not supplied)
to secure the driver.
21