Table Of Contents; Introduction; Safety - GE Druck DPI 821 User Manual

Thermocouple calibrator and thermocouple loop calibrator
Table of Contents

Advertisement

Table of Contents

Introduction ......................................................................... 1
Safety ..................................................................................... 1
To start .................................................................................. 2
To start - Location of items ........................................................ 2
To start - Items on the display .................................................. 2
To start - Prepare the instrument ........................................... 2
To start - Power on or off ............................................................ 3
To start - Set up the basic operation ..................................... 3
To start - Set up the settings ..................................................... 4
To start - Edit functions ................................................................ 5
Operation .............................................................................. 6
Operation - Thermocouple connections .............................. 6
Operation - Measure thermocouple values ....................... 6
Operation - Change the output values ................................. 6
Operation - Transmitter calibration ....................................... 7
Operation - mA measurements ............................................... 8
Operation - Switch test ................................................................ 8
Operation - UPM Pressure measurements ......................... 9
Operation - Error indications ..................................................... 9
Maintenance ..................................................................... 10
Maintenance - Clean the unit ................................................ 10
Maintenance - Replace the batteries ................................ 10
Calibration ......................................................................... 10
Calibration - Before you start ................................................. 10
Calibration - Procedures (CJ input) ...................................... 11
Calibration - Procedures (mA input) .................................... 11
Calibration - Procedures (IDOS UMM) ................................. 11
Specification data ............................................................ 11
Specification - General .............................................................. 11
Specification - Temperature ranges ................................... 12
Specification - mV range .......................................................... 12
Specification - Electrical connectors (A2) ......................... 12
Customer service ............................................... Back cover
© 2005 General Electric Company. All rights reserved.
Trademarks
All product names are trademarks of their respective companies.
K346 Issue 2

Introduction

The DPI 821 Thermocouple Calibrator and DPI 822
Thermocouple Loop Calibrator are part of the Druck
DPI 800 series of hand held instruments.
The DPI 800 series uses Intelligent Digital Output Sensor
(IDOS) technology to give instant plug and play
functionality with a range of Universal Measurement
Modules (UMM). Example: the Universal Pressure Module
(UPM).
The DPI 821/822 include these functions:
Function
Measure/simulate
thermocouple temperature
or mV
Cold Junction (CJ)
compensation
Step/Ramp functions
Communications port
Language selection
Measure pressure/Leak test
** Snapshot
Measure mA
®
HART
resistor
V dc output
Switch test
Other functions
*
Refer to "Specification data".
** Optional item

Safety

Before you use the instrument, make sure that you read
and understand all the related data. This includes: all local
safety procedures, the instructions for the UMM (if
applicable), and this publication.
• It is dangerous to ignore the specified limits for the
instrument or to use the instrument when it is not in
its normal condition. Use the applicable protection
and obey all safety precautions.
• Do not use the instrument in locations with explosive
gas, vapor or dust. There is a risk of an explosion.
DPI 821
DPI 822
* Yes
Automatic/Manual
Automatic/Manual
IDOS or RS232
Yes
** External IDOS UPM
Up to 1000 displays with a
date/time stamp
No
0 - 55 mA
No
Yes
No
24 V
No
Yes
Hold, Maximum/Minimum/Average,
Filter, Tare, Scaled values, Backlight,
Alarm
WARNING
[EN] English - 1
Continued

Advertisement

Table of Contents
loading

This manual is also suitable for:

Druck dpi 822

Table of Contents