Ford Historic (OBD I) Diagnostics
4. Wiggle Test instructions.
•Use the
instructions or not.
•Press
Instructions are available for
viewing. The default is Yes. If No is
selected, the test begins to
initialize.
If Yes is selected, the following instructions appear.
Gently tap and shake the sensor.
Wiggle the sensor connectors.
Twist and shake the wiring between the sensor and the PCM.
5. Start KOEO/KOER Wiggle Test.
•Press
After the 10-second initialization
period, the Scan Tool is ready for
the Wiggle Test. Locate the
suspect sensor or circuit
according to the above
instructions.
If a fault is detected, the Scan Tool
beeps and displays a FAULT
PRESENT message. A DTC(s) is
stored in the PCM and the Scan
Tool.
6. Return to On Demand Test
Menu.
•Press
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 6 – 21
LEFT or
RIGHT arrow key to view wiggle test
to continue.
ENTER
.
ENTER
.
BACK
KOEO Wiggle Test
View instructions
for wiggle test?
<Yes>
No
KOEO Wiggle Test
Wiggle Test Running.
Status:
*** Circuit OK ***
KOEO Wiggle Test
Wiggle Test Running.
Status:
*** Fault Present ***
6