5.

Service Mode

5.1.

Service Autotest

End users can only see E1-E2-E3-E4. During service autotest, other failures can be seen.
1.
To activate service autotest, Press SW4 button and simultaneously position program knob to 1.
2.
After 3 sec, door will be locked , after door is locked, all leds will be fix OFF and machine will get into service autotest mode.
The test steps are as below ;
Step 1
:
Selector position 1 will be "HEATER ON"
Before heating it should take water till first level frequency then start
heating.
Heater will be on max. 8 minutes.If temperature doesn't increase 2°C
in 8 minutes,machine will give NTC failure. ( E05 ).
Or if the NTC connection is broken then it should give again E05 NTC
failure.
L2 and L4 should fast blink during E05 error.
At the end of heating, "SAU" visualization should make slow blink to
indicate that the step is over.
Note : If user changes the selector position, machine will do what is
defined for the new selected position.
Step 2
:
Selector position 2 will be "PUMP ON"
Temperature will be measured, if it is higher than 50°C, it should take
80sec. cooling water and then make "Drain+ 5sec.)
At the end of pump activation, "SAU" visualization should make slow
blink to indicate that the step is over.
Step 3
:
Selector position 3 will be "RAPID 15' "
So machine will make exactly the same algorithm of Rapid 15'.
So, time for selector position 1 is 15 minutes.
At the end of Rapid 15' the door will be unlocked and machine will go
to END mode.
Selector
Position 1
Result
HEATER ON
When
entering in
Comments :
service test,
door will be
locked.
Selector
Selector
Position 2
Position 3
Result
Result
TEST
PUMP ON
PROGRAM ON
TEST IS OVER
Door will be
unlocked,
machine will go
to END state.
LD1  Star/ Pause Led  Slow Blink
LD2  Wash Phase Led  Slow Blink
LD3  Rinse Phase led  Off (Except Rinse program. For Rinse
program L2 makes slow blink)
LD4  Spin Phase Led  Off (Except Spin program. For Spin
program L4 makes slow blink.)
LD5  Delay Timer Led  Off (If it is selected  On)
LD6  Function Led  Off (If it is selected  On)