reach the limit, both data will back to zero. Also can set the data back to
zero in the system setting.
D. Set Parameter Display: This area display current working state, pump
head, tubing size and suck-back angle
E.
Date and Time Display: Display the current date and time, can amend it
in system settings
F.
System Setting Button: Press this button enter system setting interface,
include set the pump head and tube size, set the suck-back angle, set
common mode, set current date and time.
G. Flow Calibration Button: Press this button enter calibration interface.
H. Real-time Monitor Button: Press this button enter monitor interface,
you can check the flow rate, motor speed and dispensing efficiency here.
I.
Dispensing Volume Button: Press this button, the numerical keyboard
come out, input the dispensing volume here
J.
Time Button: Press this button, the numerical keyboard come out, input
the filling time. Click confirm, it will ask whether continue to input the
pause time, choose 'YES', you can input the pause time, choose 'NO',
back to the main interface
K. Copy Numbers Button: Press this button, the numerical keyboard come
out, input the copy numbers. If input '0', the copy number is unlimited
4.3. Basic Configuration Interface:
- 4 -
F Series