MANUFACTURER'S PLACEMENT INSTRUCTIONS

PROPER ASSEMBLY, INSTALLATION, USE, AND SUPERVISION ARE ESSENTIAL FOR PROPER
OPERATION AND TO REDUCE THE RISK OF SERIOUS INJURY.
THE SLIDE OWNER MUST CONFIRM THAT THE MANUFACTURER'S PLACEMENT INSTRUCTIONS
1. The critical dimensions for placement of the Turbotwister are as shown in FIGURE B and FIGURE C
A. The slide exit runway surface shall not exceed 20" (508 mm) above the water surface as
shown in FIGURE B.
B. The slide shall be positioned so that all water flowing off the runway exit drops into the pool.
Recommended overhang is 4" (102 mm).
C. The minimum depth of water below the exit lip of the slide shall be 3' (914 mm) and increases
to 4'-6" (1372 mm) at Pt. A, which is a distance of 4'-6" (1372 mm) from the exit lip of the
slide as shown in FIGURE B.
A minimum depth of 4'-6" (1372 mm) shall be maintained at a distance of 9' (2743 mm) along
D.
the extended centerline of the slide from Pt. A. as shown in FIGURE B.
2. A minimum clearance area in front of the slide shall be maintained at all
times as follows:
A. The minimum clearance distance on either side of the extended
centerline of the slide runway shall not be less than 3'-6" (1067 mm)
at a point no less than 2'-6" (762 mm) from the exit lip of the slide
and extending a distance of 13'-6" (4115 mm) in front of the slide as
shown in FIGURE C
B. The minimum clearance area in front of a properly installed diving
board on an inground swimming pool is a minimum distance of 3'-6"
(1067 mm) on either side of the board's centerline as shown in
FIGURE D. Pt. C extends a minimum distance of "C" from the tip
end of the board as shown in FIGURE D. The width distance "W" on
either side of Pt. C is given in FIGURE D and shown in FIGURE D.
HAVE BEEN FOLLOWED BY THE INSTALLER.