Crankcase Ventilation System - WÄRTSILÄ 46DF Product Manual

Table of Contents

Advertisement

Wärtsilä 46DF Product Guide
7.3.9
Safety filter (2F05)
When off-engine main filter, a separate safety filter (2F05) must be installed before the engine,
unless it is integrated in the automatic filter. The safety filter (2F05) should be a duplex filter
with steelnet filter elements.
Design data:
Oil viscosity
Design flow
Design temperature
Design pressure
Fineness (absolute) max.
Maximum permitted pressure drop at 50 cSt:
- clean filter
- alarm
7.3.10
Automatic filter, backflush flow (2F13)
When on-engine filter, It is recommended to select an automatic filter with an insert filter in
the backflushing line, thus enabling easy changeover to the insert filter during maintenance
of the automatic filter. Clean oil from backflush filter can go directly to oil tank. Some backflush
filter models operates properly when they have a moderate counterpressure at clean oil
discharge, thus these models have a simple pressure regulating valve afterwards.
Backflush filter sludge oil must be discharged to sludge tank, when no further post-filtration
occurs. To be re-used, it must be filtered by a sludge cartridge filter before it is conducted
back to the system oil tank. The sludge cartridge filter can be either integrated in the automatic
filter or separate. A bypass line discharging the oil from on-engine filter directly to tank
allowsbackflush filter maintenance, which should be bypassed for less time as possible.
Design data:
Oil viscosity
Design flow
Design temperature
Design pressure
Fineness (absolute) max.
- automatic filter
- sludge cartridge filter
Maximum permitted pressure drop at 50 cSt:
- clean filter
- alarm
7.4

Crankcase ventilation system

The purpose of the crankcase ventilation is to evacuate gases from the crankcase in order to
keep the pressure in the crankcase within acceptable limits.
DBAD209883
50 cSt (SAE 40, VI 95, appox. 63°C)
see Technical data, "Oil flow through engine"
100 °C
1.0 MPa (10 bar)
60 µm (mesh size)
30 kPa (0.3 bar )
80 kPa (0.8 bar)
50 cSt (SAE 40, VI 95, appox. 63°C)
17 m3/h for Line engines, 25 m3/h for Vee engines
100 °C
1.0 MPa (10 bar)
34 µm (mesh size), corresponding to approx 50 µm absolute
50 µm (absolute
30 kPa (0.3 bar )
80 kPa (0.8 bar)
7. Lubricating Oil System
7-19