SECTION 12: Motor Protective Devices - 50/60 Hz
12.1 How They Work
Pentek
motor protectors are designed to protect single
®
phase pumps from dry run, dead head, jammed impeller,
and over & under voltage conditions.
A calibration adjustment allows the motor protector to
be calibrated to specific pumping applications, thereby
reducing the possibility of false or nuisance tripping. A
micro drive based voltage and current sensing circuit
monitors for power fluctuations, over-current, and under-
current conditions. When an abnormality, such as loss
of suction, is detected, the motor protector deactivates
its output relay and immediately disconnects the pump
motor. The motor protector then activates its user-
12.2 Specifications
Parameter
1 Phase Line Voltage (±10%)
Load Range
Frequency
Power Consumption (Maximum)
Operating Temperature
Electrostatic Discharge (ESD)
Output Contact Rating (SPST)
Weight
Enclosure
Current Transformer Ratio
Operating Points
Overload
Underload (Dry Run)
Overvoltage Trip Point
Undervoltage Trip Point
Nu mber of Restarts allowed in a 60 sec.
Period before lockout (Rapid Cycle
Timer)
Trip Delay Time (Overload)
Trip Delay Time (Dry Run)
Restart Delay Time
Overvoltage/Undervoltage Delay
Al l other faults (Dry Run Rec. Timer)
Terminal
Wire Gauge
Maximum Torque
selectable "Restart Delay" (Dry run recovery) timer.
When the timer counts to zero or power is removed and
reapplied, the motor protector reactivates its output relay
and turns the pump back on.
An infrared LED communicates directly with a hand-held
diagnostics tool called the Informer (sold separately). The
Informer displays 16 parameters including calibration
point, trip point, running points, and last fault.
NOTICE: The use of flow restrictors or unusually high
head pressures at the time of calibration may interfere
with the detection of dead head conditions.
SPP-111P
SPP-111P-3RL
115 VAC
1/3 - 1/2 HP
1/3 - 1 HP
(.25 - .37 kW)
(.33-.75 kW)
IEC 1000-4-2, Level 2, 4kV Contact, 6 kV Air
1/2 HP @ 115 VAC
1 HP @ 115 VAC
(17 AMPS MAX)
(17 AMPS MAX)
1.6 lbs (.73 kg)
.63 lbs (.28 kg)
w/enclosure
None
NEMA 3R
N/A
N/A
132.5 VAC
95 VAC
N/A
SPP-231P
SPP-233P
230 VAC
1/3 - 1 HP
1/3 - 3 HP
(.25 - .75 kW)
.25 - 2.24 kW)
50-60 Hz
5 W
-40° to 158° F (-40° to +70° C)
1 HP @ 240 VAC
3 HP @ 240 VAC
(17 AMPS MAX)
(17 AMPS MAX)
.63 lbs (.28 kg)
None
N/A
N/A
125 % of Calibration Point
~80% of Calibration Point
265 VAC
190 VAC
4
5s
2s
5s
2-225 min
SPP-235P-XX
5 - 15 HP
(3.73 - 11.19 kW)
480 VA @ 240 VAC
1.6 lbs (.73 kg)
NEMA 3R w/ LENS
SPP-235-75 – 50:5
SPP-235-100 - 75:5
SPP-235-150 -
100:5
12-22
7 in-lbs
87