SECTION 9: PPC Series 50/60 Hz Variable Frequency Drives
9.6.4 Step By Step Programming
Instructions
STEP 1
Initial Startup Panel Display
Upon initial drive power-up the installer will be prompted
to run the Pentek
Assistant. Scroll to YES and then
®
select OK. Wait while the program loads. On subsequent
startups, the Pentek Assistant can be found in the
ASSISTANTS menu.
CHOICE
REM
Do you want to run
the PENTEK
assistant?
Y es
No
00:00
EXIT
STEP 2
Motor Selection Screen
Scroll to select the type installation and then press OK.
Please Select Mtr Type
Above Ground
Submersible
00:00
EXIT
STEP 3
Motor Voltage Screen
The screen shows motor voltage. Scroll to select the
correct voltage for your motor as stated on the motor
nameplate. This sample shows 460 volts. Press SAVE.
PAR EDIT
REM
9905 MOTOR NOM VOLT
460 V
00:00
EXIT
STEP 4
Motor Current Screen
Enter the motor current from the motor nameplate
(not maximum amps). Scroll to select the current and
press SAVE unless it is a submersible (more than 1.15).
STEP 5
OK
Motor Frequency Screen
Enter the motor frequency (Hz) from the motor
nameplate. Scroll to select the frequency and select
SAVE.
OK
STEP 6
Motor Speed Screen
Enter the motor speed (RPM) from the motor nameplate.
Scroll to select the speed and press SAVE. The sample
here shows 3450 RPM.
SAVE
PAR
EDIT
REM
9906 MOTOR NOM CURR
3.8 A
00:00
EXIT
SAVE
PAR EDIT
REM
9907 MOTOR NOM FREQ
60.0 Hz
00:00
EXIT
SAVE
PAR EDIT
REM
9908 MOTOR NOM SPEED
3450 rpm
00:00
EXIT
SAVE