Use two insertion profiles running perpendicularly to
the long side frame. An additional support bar should
be placed below the module. Use two clamps on the
support bar.
Maximum Load:
Uplift load
≤
2400 Pa
Downforce load
≤
5400 Pa
MOUNTINg METhOD C: MOUNTINg
METhODS wITh (SINgLE-AXIS TRACkER)
· Canadian Solar Inc. modules can be mounted on
single-axis trackers using center clamps or mounting
holes as described below. All the requirements of
the standard module installation manual and specific
tracker detailed installation instructions should apply.
· The following tracker manufacturers and types are
approved with Canadian Solar modules.
Module
Compatible
Type
Tracker
CS3U-P, CS3U-
MS, CS6U-P,
ATI DuraTrack™HZ
CS6U-M,
Tracking System(V3)
CS3W-P
CS3U-P, CS3U-
NEXTracker NX
MS, CS6U-P
Horizon
and CS6U-M
NEXTracker NX
CS3W-P
Horizon
CS3U-P, CS3U-
NEXTracker NX
MS, CS6U-P
Horizon
and CS6U-M
Arctech
single-axis tracker
CS3U-P
Portrait two rows
Mounting Rail
Mounting
Maximum Load (pa)
hardware
Clamp Ear (V3)
Downforce load ≤
400 mm Short Rail
(mounting holes)
Downforce load ≤
V2.3 Top Clamp Rails
Rail part No: 20899,
Downforce load ≤
20934, 20907
V2.3 Top Clamp Rails
Rail part No: 20899,
Downforce load ≤
20942, 20908
3438 mm rail
(bolting method /
M8 bolt + M8 plain
washer (O.D. = 24
mm) /
Downforce load ≤
1155 mm holes
position)
Rail drawing No:
CS2018002
Reference Manual
(version No.)
Uplift load ≤
DuraTrack™HZ Solar
2400 Pa
Tracker Installation Guide
(January 2017, Rev. B-01)
2400 Pa
Uplift load ≤
NEXTracker NX Horizon
2400 Pa
Installation Manual
2400 Pa
(PDM-000149 Rev. B)
Uplift load ≤
NEXTracker NX Horizon
2400 Pa
Installation Manual
2400 Pa
(PDM-000149 Rev. B)
Uplift load ≤
NEXTracker NX Horizon
2400 Pa
Installation Manual
2400 Pa
(PDM-000149 Rev. B)
Uplift load ≤
2400 Pa
SSMFIM-rev01
(SkySmart-Module Fixing
2400 Pa
Installation Manual)
www.canadiansolar.com
| 17
2.3.1
2.3.1
2.3.1