Canadian Solar CS3U-MS-FG Installation Manual

Dymond module

Advertisement

Quick Links

INSTALLATION
MANUAL OF
DYMOND MODULE
For professional use only

Advertisement

Table of Contents
loading

Summary of Contents for Canadian Solar CS3U-MS-FG

  • Page 1 INSTALLATION MANUAL OF DYMOND MODULE For professional use only...
  • Page 2: Table Of Contents

    MODULE GROUNDING MOUNTING INSTRUCTIONS | 10 MAINTENANCE | 10 AMENDED EDITIONS AND DATES | 11 ANNEX A: MECHANICAL AND ELECTRICAL RATINGS | 14 ANNEX B: DOUBLE GLASS MODULE INSTALLATION MANUEL SUPPLEMENT EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.
  • Page 3: General Information

    The information contained in this manual is subject GENERAL SAFETY to change by Canadian Solar Inc. without prior notice. Canadian Solar Inc. gives no warranty of any · All modules must be installed by licensed electricians kind whatsoever, either explicitly or implicitly, in accordance with the applicable electrical codes with respect to the information contained herein.
  • Page 4: Information Pursuant To Art. 33 Of The

    (EC) No 1488/94 as well as Council Directive circuit current under STC should be multiplied by 76/769/EEC and Commission Directives 91/155/EEC, 1.25 when determining component voltage ratings, 93/67/EEC, 93/105/EC and 2000/21/EC (the “REACH conductor ampacities, overcurrent device ratings, EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.
  • Page 5: Unpacking And Storage

    (roof, facade, in turn may compromise module reliability and support, etc.) can bear the module system load. void Canadian Solar Inc’s warranty. · Canadian Solar Inc. double glass solar modules www.canadiansolar.com...
  • Page 6 · The module is intended for use in general open-air protection device is installed in series with each climates, as defined in IEC 60721-2-1: Classification string. of environmental conditions Part 2-1: Environmental EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.
  • Page 7: Module Wiring

    OPTIMUM ORIENTATION AND TILT connectors. · To maximize your annual yield, find out the optimum · For CS3U and CS3K series modules, Canadian Solar orientation and tilt for PV modules in your region. Inc. offers optional cable specifications to match The highest yields are achieved when sunlight various system configurations.
  • Page 8 (i.e. TUV 2PfG1169 or EN50618 Electrical Code (NEC). approved), with proper insulation which is able to withstand the maximum possible system open-cir- · Proper equipment grounding is still required for EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.
  • Page 9: Mounting Instructions

    · Clamp material should be anodized aluminum alloy or steel of appropriate grade. One buffer rubber material (Recommended material is EPDM) must be added between the clamp and the glass. · Canadian Solar Inc. warranty may be void in cases Rail Bolt Bottom End Clamp...
  • Page 10: Maintenance

    · Please refer to our Installation Manual Annex of standard solar modules (Section Annex D: Module Cleaning Guideline) for more information on this topic. EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.
  • Page 11 | 11 ANNEX A: MECHANICAL AND ELECTRICAL RATINGS Standard Test Conditions are: irradiance of 1 kW/m within ±10 percent or [0; +5 W] of the indicated valu- air mass (AM) spectrum of 1.5, and cell temperature es for Isc, Voc and Pmax. Specifications are subject of 25°C.
  • Page 12 38.5 9.43 box and CS6K-285M-FG 31.7 8.98 38.6 9.51 corner CS6K-290M-FG 31.9 9.09 38.7 9.59 protector CS6K-295M-FG 32.1 9.19 38.9 9.68 CS6K-300M-FG 32.4 9.25 39.1 9.78 CS6K-305M-FG 32.5 9.38 39.2 9.89 EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.
  • Page 13 | 13 Maximum Operating Operating Open Circuit Short Circuit Max. Series Overall Weight Module Type Power voltage current Voltage Current Fuse Dimension <kg> Pmax <W> Vmp <V> Imp <A> Voc <V> Isc <A> Rating <A> <mm> CS6K-250MS-FG 30.5 37.7 9.03 CS6K-255MS-FG 30.7 8.31...
  • Page 14 Mounting rails must run perpendicularly to the module long side. module long side. The following clamps in table 2 have been approved as compatible with Canadian Solar double glass module CS6K-P-FG, CS6K-M-FG and CS6K-MS-FG. EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.
  • Page 15 | 15 Table 2: CS6K-P-FG, CS6K-M-FG and CS6K-MS-FG compatible clamps Mounting Clamp Quantity Certification Supplier Clamp Image Clamp Type & length Load (Pa) Method & Location Body four clamps, Downforce load≤2400 Pa 2-A-1 A=380±20 mm, VDE / CSA Uplift load ≤2400 Pa see illustration A SA-TOK-UA (End clamp) NISSEI METALS...
  • Page 16 B=579±20 mm, Uplift load ≤2400 Pa clamp length=100 mm see illustration B The following clamps in table 3 have been approved as compatible with Canadian Solar double glass module CS6X-P-FG and CS6X-M-FG. EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.
  • Page 17 | 17 Table 3: CS6X-P-FG and CS6X-M-FG compatible clamps Mounting Clamp Quantity Certification Supplier Clamp Image Clamp Type & length Load (Pa) Method & Location Body SA-TOK-UA (End clamp) six clamps, NISSEI METALS / SA-KOK-UA (Middle A=300±20mm, Downforce load≤2400 Pa 3-A-1 CO.,LTD.
  • Page 18 Downforce load≤5400 Pa 3-F-4 VDE / CSA clamp), B=684±20 mm, Uplift load ≤2400 Pa clamp length=130 mm see illustration B The following clamps in table 4 have been approved as compatible with Canadian Solar double glass module CS3K-MS-FG and CS3K-P-FG.
  • Page 19 Technology A=380±20 mm, VDE / CSA clamp), Uplift load ≤2400 Pa see illustration A (Suzhou) Co.,Ltd. clamp length=200 mm The following clamps in table 5 have been approved as compatible with Canadian Solar double glass module CS3U-MS-FG and CS3U-P-FG. www.canadiansolar.com...
  • Page 20 A=440±20 mm, VDE / CSA clamp), Uplift load ≤2400 Pa see illustration A (Suzhou) Co.,Ltd. clamp length=250 mm CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario, Canada N1K 1E6 www.canadiansolar.com EN-Rev IM-FDM-EU/1.7 Copyright © April 2019. Canadian Solar Inc.