CS3k-p, CS3k-MS, CS6k-p, CS6k-M, CS6k-MS, CS6v-p, CS6v-M and CS6v-MS
Use two insertion profiles running parallel to the long
side frame.
Maximum Load:
Uplift load
≤
2400 Pa
≤
Downforce load
4000 Pa
Use two insertion profiles running perpendicularly
to the long side frame. An additional support
bar should be placed below the module. Use two
clamps on the support bar.
Maximum Load:
≤
Uplift load
2400 Pa
Downforce load
≤
5400 Pa
CS6A-p, CS6A-M, CS6vL-MS and CS6A-MS
Use two insertion profiles running parallel to the long
side frame.
Maximum Load:
Uplift load
≤
2400 Pa
≤
Downforce load
4000 Pa
Use two insertion profiles running perpendicularly to
the long side frame.
Maximum Load:
Uplift load
≤
2000 Pa
≤
Downforce load
2000 Pa
Use two insertion profiles running perpendicularly to
the long side frame.
Maximum Load:
Uplift load
≤
2400 Pa
Downforce load
≤
2400 Pa