DIGITAL CONTROL INTERFACE
SET DATE AND TIME
The time controls all scheduled times, functions, and programmed cycles and stores the correct time for up
to 96 hours after power is turned off. Reset if the power is off longer than 96 hours.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Date and Time" and press Select.
5. Press Select again and use Up or Down arrows to set the date.
6. Press Enter to save user input and return to "Date and Time."
7. Use the Up or Down arrows to scroll to "Time" and press Select.
8. Use the Up or Down arrows to scroll to set the time. Note: To set AM/PM or a 24 hour clock see the next
section "Set AM/PM or 24 Hour Clock."
9. Press Enter to save. To cancel any changes, press Escape to exit without saving.
10. Press Escape to exit.
SET AM/PM OR 24 HOUR CLOCK
To change the time from a 12 hour clock (AM/PM) to a 24 hour clock:
1. Press Menu.
2. Press Select to select "Settings".
3. Use the Up or Down arrows to scroll to "Date and Time" and press Select.
4. Use the Up or Down arrows to scroll to "AM/PM" and press Select.
5. Use the Up or Down arrows to scroll to choose between 24 hr. and AM/PM.
6. Press Enter to save. To cancel any changes, press Escape to exit without saving.
7. Press Escape to exit.
SET MINIMUM SPEED (RPM)
The minimum pump speed can be set from 450 RPM to 1700 RPM. The default setting is 450 RPM.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Min/Max".
5. Use the Up or Down arrows to scroll to "Set Min Spd".
6. Press Select to change the setting. The cursor will appear in the first number column (ones).
7. Press the Up or Down arrows to change the minimum speed setting from 450 to 1700 RPM.
8. Press Enter to save. To cancel, press Escape to exit edit mode without saving.
9. Press Escape to exit.
PUMP ADDRESS
This setting is reserved for connecting pump via the port to an automation system. No function at present.
SET SCREEN CONTRAST
The default setting for the LCD screen is 15. Screen contrast levels can be adjusted from 0 to 30 units for
low or high lighting conditions. Note: Changes to the contrast setting do not update instantaneously.
Changes to this setting must be saved before the contrast level changes.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrow to scroll to "Device" and press Select.
5. Use the Up or Down arrow to scroll to "Contrast Level."
6. Press Select. Screen will show current contrast setting number. Use Up or Down to change number.
7. Press Escape to save. To cancel any changes, press Escape to exit without saving.
8. Press the Escape button to exit.