INSTALLATION

PUMP LOCATION

Installing union connections at the suction and outlet ports is recommended, to facilitate servicing of pump
and to allow for indoor storage during the winter months.
Use Teflon tape to seal threaded connections on molded plastic components. All plastic fittings must be
new or thoroughly cleaned before use. NOTE: DO NOT use Plumber's Pipe Dope as it may cause cracking
of the plastic components.
When applying Teflon tape to plastic threads, wrap the entire threaded portion of the male fitting with one
to two layers of tape. Wind the tape clockwise as you face the open end of the fitting, beginning at the end
of the fitting.
The pump suction and outlet ports have molded-in thread stops. DO NOT attempt to force hose connector
fitting past this stop. It is only necessary to tighten fittings enough to prevent leakage. Tighten fitting by
hand and then use a tool to engage fitting an additional 1 ½ turns. Use care when using Teflon tape as
friction is reduced considerably; DO NOT over-tighten fitting or you may cause damage. If leaks occur,
remove connector, clean off old Teflon tape, re-wrap with one to two additional layers of Teflon tape, and
re-install connector.
Fittings restrict flow. For better efficiency, use the fewest possible fittings (but at least two suction outlets).
Avoid fittings that could cause an air trap. Pool and spa fittings MUST conform to the International
Association of Plumbing and Mechanical Officials (IAPMO) standards. Use a non-entrapping suction
fitting in pool (multiple drains) or double suction (skimmer and main drain).

PUMP MOUNTING

Install pump on a firm, level base or pad to meet all local and national codes. Fasten pump to base or pad
with screws or bolts to further reduce vibration and stress on pipe or hose joints. The base MUST be solid,
level, rigid, and vibration free.
Pump mount must:
Allow pump inlet height to be as close to water level aspossible.
Allow use of short, direct suction pipe (to reduce friction losses).
Allow for gate valves in suction and discharge piping.
Be protected from excess moisture and flooding.
Allow adequate access for servicing pump and piping.
NOTE: It is recommended that a minimum length of piping, equivalent to 10 pipe diameters, be used
between the pump suction inlet and any plumbing fittings.
Fasten pump to base or pad with screws or bolts to reduce vibration and stress on pipe or hose joints.
We recommend a minimum clearance around the pad of 18 to allow adequate access for servicing
pump and piping.
13