5. Press the
(keeping pressed the
means left shift).
6. Hang the calibration weight and wait for 4 – 5 seconds until the stable
sign light on.
7. Press the
after, the display will show the weight calibration value. Calibration is
over by now. Put down the weights and power off the scale.

PARAMETERS SETTINg

Parameters setting using the remote controller

1. Post holding down the D key and so display "CAL SP".
2. Press the D key to display "SET".
3. Press the A key on remote control to display "dx" (division parameter).
4. Use the D key to change the division value.
5. When finished, press the A key to view the capacity of the crane scale.
6. Press the D key to change the capacity value.
7. Press the A key to show "fLT 00" (filter parameter 0 – 4).
8. Press the D key to change the filter value.
9. Press the A key to show "rng 1" (zero tracking parameter).
10. Press the D key to change the zero tracking value.