Installation and Wiring Instructions for the VA100 Lo-Carbon SELV Range of
Extractor Fans.
IMPORTANT:
READ THESE INSTRUCTIONS
BEFORE COMMENCING THE
INSTALLATION
DO NOT install this product in areas where the following may be present or occur:
• Excessive oil or a grease laden atmosphere.
• Corrosive or flammable gases, liquids or vapours.
• Ambient temperatures higher than 40°C or less than –5°C.
• Possible obstructions which would hinder the access or removal of the Fan.

SAFETY AND GUIDANCE NOTES

A. All wiring to be in accordance with the current I.E.E. Regulations, or the
appropriate standards of your country and MUST be installed by a suitably
qualified person.
B. The Fan should be provided with a local isolator switch capable of disconnecting
all poles, having a contact separation of at least 3mm.
C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the
rating label.
D. The Fan should only be used in conjunction with the appropriate Vent-Axia
products.
E. The fan should only be used in conjunction with fixed wiring.
F. When the Fan is used to remove air from a room containing a fuel-burning
appliance, ensure that the air replacement is adequate for both the fan and the
fuel-burning appliance.
G. The Fan should not be used where it is liable to be subject to direct water spray
for prolonged periods of time.
H. Where ducted Fans are used to handle moisture-laden air, a condensation trap
should be fitted. Horizontal ducts should be arranged to slope slightly downwards
away from the Fan.
I. This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
J. Children should be supervised to ensure that they do not play with the appliance.
K. Stationary appliances not fitted with means for disconnection from the supply
mains having a contact separation in all poles that provide full disconnection
under over voltage category III, the instructions state that means for
disconnection must be incorporated in the fixed wiring in accordance with the
wiring rules.
IMPORTANT:- ONLY CONNECT TOGETHER PRODUCTS FROM THE VA100 LO-
CARBON SELV RANGE SINCE THE FANS ARE SPECIALLY DESIGNED TO WORK
ON 12V DC AND ARE NOT COMPATIBLE WITH OTHER VENT-AXIA
CONTROLLERS. DO NOT CONNECT MORE THAN ONE FAN TO THE
CONTROLLER.