5.5

ETS parameter description

Factory settings are in brackets
Designation
Communication objects available in ETS
when function is enabled
5.5.1

Room temperature sensor

Room temperature: Sensor correction
Room temperature: Send following change by
Room temperature: Send cyclically after
5.5.2

Room temperature control

To display this section, enable the option "Activate room temperature control" in Device
Activate room temperature control
Heating type*
Cooling type
Parameters heating / cooling type allow for adapting the controller to
the type of heating / cooling. In addition, the controller features two
control algorithms: one for continuous mode (0..100%) and one for
PWM mode (On/Off). The mode is selected via parameter "Control
value type". The control value type is identical for all operating modes.
In continuous mode, the associated PWM output is "On" at
continuous control value ≠ 0.
In PWM mode, cycle time and pulse width are adapted to the type of
heating / cooling, the setpoint, and the measured room temperature.
The min. cycle time is 12 minutes, the min. pulse width is 4 minutes.
The continuous control value issues 0% or 100% in this operating
mode.
Default heating setpoint
Default cooling setpoint
Control value type
Send cyclically after
Protection heating setpoint
Economy heating setpoint
Precomfort heating setpoint
Comfort heating setpoint
Comfort cooling setpoint
Precomfort cooling setpoint
Economy cooling setpoint
Protection cooling setpoint
Comfort extension time
Number of window status inputs
Siemens
Building Technologies
Wall-mounted sensors and room operator units for KNX/ETS and KNX/ACS
ETS engineering
Values
Range
(Default)
–5...+5 °C
in 0.1 steps (0 °C)
0.1...2.5 °C
(0.1 °C)
1...60 (2 min)
yes; no
Radiator heating slow
(Radiator heating fast)
Floor heating slow
Floor heating fast
(Chilled ceiling)
Floor cooling
5...40 (21.0)
5...40 (24.0)
(PWM)
Continuous 0...100%
Do not send cyclically
1;2;3...30;45;60
5...40 (12.0)
5...40 (15.0)
5...40 (19.0)
5...40 (21.0)
5...40 (24.0)
5...40 (28.0)
5...40 (35.0)
5...40 (40.0)
5...120 (30)
0...4
Type
K
X
X
X
X
X
X
K
X
X
X
X
X
X
X
X
X
X
X
X
min
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
°C
X
X
X
X
X
X
°C
X
X
X
X
X
X
X
X
X
X
X
X
min
X
X
X
X
X
X
X
X
X
X
X
X
°C
°C
X
X
X
X
X
X
°C
X
X
X
X
X
X
X
X
X
X
X
X
°C
°C
X
X
X
X
X
X
°C
X
X
X
X
X
X
X
X
X
X
X
X
°C
°C
X
X
X
X
X
X
min
X
X
X
X
X
X
X
X
X
X
X
X
35 / 46
CM2N1602en_05
2018-09-14
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qmx3.p74Qmx3.p34Qmx3.p02Qmx3.p30Qmx3.p40Qmx3.p70

Table of Contents