220-Volt AC Power Cord for Use in North America
The criteria for a U.S. and Canadian 220-volt AC power cord for the library are as
follows:
• Power cord must have a molded NEMA 6-15P attachment plug on one end.
• Power cord must have a molded IEC type CEE-22 female connector to connect to
the library.
• Cordage must be SJT type, three-conductor, 18 AWG minimum.
• Power cord must comply with local electrical code.
220-Volt AC Power Cord for International Use
The criteria for an international 220-volt AC power cord are as follows:
• Power cord must have an attachment plug of the proper type, rating, and safety
approval for the intended country.
• Power cord must have an IEC type CEE-22 female connector on one end to connect
the library.
• Cord must be a flexible, HAR (harmonized) type H05VV-F, three-conductor, cord
with minimum conductor size of 0.03 square inches (1.0 square millimeters).

Library Operating Environment Limits

Place the library and media in a reasonably controlled environment that does not
exceed the environment limits listed in the table below:
Condition
Operating Temperature (Ambient Outside Library)
Storage Temperature
Relative Humidity (non-condensing)
Maximum Wet Bulb Temperature
Altitude
Appendix A. Specifications
Minimum
2
C
°
35.6
F
°
-40° C
-°104 F
20%
N/A
0 m
Sea level
77
Maximum
30° C
86° F
65
C
°
149
F
°
80%
26
C
°
3,000 m
9,842 ft