C24EA SERIES ELECTRIC CONVECTION STEAMERS - WATER LEVEL CONTROL COMPONENTS
Fig. 49
7.
Remove pipe tee and nipple plumbing assembly
from drain valve.
8.
Reassemble parts removed in reverse order.
Apply pipe thread sealant to pipe threads before
installation.
NOTE: If motorized drain valve is in the open position
when power is applied to the steamer with the power
switch on, drain valve will not close and fill water will
flow through the steam generator into the drain.
9.
Verify power switch is in the off position and the
motorized drain valve is closed before applying
power to steamer.
NOTE: When power is applied and power switch is
off steamer will enter a drain cycle.
10. Check steamer for proper operation and leaks
around drain valve.
F35453 Rev. A (0119)
Page 30 of 75