C24EA SERIES ELECTRIC CONVECTION STEAMERS - TIMERS
REMOVAL AND REPLACEMENT
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
NOTE: When the timer reaches zero, an external
buzzer will sound and steam will stop entering the
cooking compartment. The constant steam setting
allows for continuous steam operation.
1.
Remove COOKING COMPARTMENT RIGHT
SIDE PANEL as outlined under Covers and
Panels.
2.
Note electrical connections then disconnect
wiring from timer being serviced.
Fig. 27
3.
Pull knob from timer shaft.
A.
Remove rotary shaft seal from timer shaft
then remove timer from front panel.
B.
Inspect rotary shaft seal. Replace if
damaged, worn or signs of moisture
migration into control area around timer
shaft is evident.
F35453 Rev. A (0119)
TIMERS
4.
Reverse procedure to install.
5.
Check steamer for proper operation. Upper
compartment shown.
Page 18 of 75
Fig. 28