A. Make sure that the wall covering, conter top, flooring and cabinets around the range can
withstand the heat (uo to 200°F) generated by the range.
B. Allow 76,2 cm ( 30 " ) minimum clearance between surface units and bottom of unprotected
wood or metal cabinet, or allow 61 cm ( 24 ") minimum when bottom of wood or etal cabinet is
protected by no less than 0,6 cm ( 1 / 4 " ) thick flame retardant milboard covered with not less
than No 28 MSG sheet metal, 0.38 mm ( 0.015 ") thinck stainless steel , 0.61 mm (0.024 ")
aluminum or 0.51mm (0.020 ") copper.
C. This apppliance has been approved for 0" minimum spacing to adjacent surfaces above the
cooktop. However, a 15.2 cm minimum spacing to surfaces less than 30.81 cm above the cooktop
and adjacent cabinets is recommended to reduce exposure to steam, grease and heat.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage
space above the cooktop should be avoided. If cabinet storage space is to be provided above the
cooktop, the risk can be reduced by installing a range hood that projects at least 12.7 cm beyoond
the front od the cabinets. Cabinets installed above the cooktop must be bo deeper than 33 cm.
Cuando el revestimiento del suelo termina en la parte delantera de la gama, el área que la gama
descansará y debe ser construido con madera contrachapada para el mismo nivel o más alto que
el revestimiento del suelo. Esto permitirá que la estufa sea movida para la limpieza o el
mantenimiento.
Ingeniería de Servicio