5.5

Reviewing Q-Vet Results

After running Q-Vet, check the results by reviewing the summary log.
Q-Vet will run all exercisers until the slowest device has completed one full pass.
Depending on the size of the system, this will typically take 2 to 12 hours. Q-Vet will then
terminate testing and produce a summary log. The termination message will tell you the
name and location of this file.
All exerciser processes can also be manually terminated with the Suspend and Terminate
buttons (stop and terminate commands).
After all exercisers report "Idle," the summary log is produced containing Q-Vet specific
results and statuses.
A. If there are no Q-Vet errors, no system error events, and testing ran to specified
completion, the following message will be displayed:
Q-Vet Tests Complete: Passed
B. Otherwise, a message will indicate:
Q-Vet Tests Complete: Fail
Run Compaq Analyze to review test results. The IVP scripts do not translate events unless
they are Q-Vet detected errors. The testing times (for use with Compaq Analyze) are printed
to the Q-Vet run window and are available in the summary log.