HP AlphaServer ES47 Upgrade Manual page 63

Hide thumbs Also See for AlphaServer ES47:
Table of Contents

Advertisement

.|........
.|........
2 .P........
.|........
.|........
3 .P........
.w........
<< ------------ lines deleted ------------- >>
Running test 10, Initialize RAMBUS ... on 4 EV7s
Running test 11, Initialize Memory ... on 4 EV7s
<< ------------ lines deleted ------------- >>
Running test 43, Software Alerts ... on 1 EV7s
Running test 46, Other Local Interrupt Bits ... on 4 EV7s
<< ------------ lines deleted ------------- >>
MBM>
To check your cable connection:
1. Enter the command show cable
2. The system prints out a cabling diagram.
ID0 connects to your north port of the top drawer, in this case, drawer ID1. Detailed
diagram of the cables shown in Figure 3-4.
3. Drawer ID0 in cabinet 0 (0,0)
4. The table at
shows how the PCI I/O is connected to the CPUs:
The first line reports that the I/O port of CPU0 in drawer 0 is connected to the IO7
chip in drawer 0. The second line reports that the I/O port of CPU0 in drawer 1 is
connected to the IO7 chip in drawer 1.
5. Enter the command p on
6. Confirm that all of your CPUs are configured—in this example, 4.
checked and reported.
indicates where your south port from drawer
is cabled to drawer ID1 in cabinet 0 (0,1)
to power on.
Configure and Troubleshoot
.
Each CPU is
4-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alphaserver es47 m4Alphaserver es47 m2

Table of Contents