Ma) Manual Operation Frame - Fujitsu S120 Series Operating Manual

Table of Contents

Advertisement

User frames and subframes

6.4.4 (MA) MANUAL OPERATION FRAME

FUNCTION=>
*1 RATE CONTROL
*2 ADRS COMPARE STOP
*3 FIRMWARE DUMP
*4 HSA DUMP
*X EXECUTE
E2M31 CPU NOT IN STOPPED STATE
RA
Figure 30: MANUAL OPERATION FRAME screen
By making an entry in this frame and pressing
operations.
Instructions on this frame are only executed when the CPU has been stopped
(see message in frame line 23). The CPU status is displayed in line 22.
Ê
Stopping of the CPU (see (ML) MODE SELECTION FRAME page 48)
FUNCTION =>
1
2
3
4
X EXECUTE
58
----- MANUAL OPERATION FRAME -----
CL-0
The following function is executed after the corresponding charcacter
has been entered:
RATE CONTROL
ADRS COMPARE STOP
FIRMWARE DUMP
HSA DUMP
RATE CONTROL=>
*1 PROCESS
*2 I-STEP
UNIT ADRS=> 0000
CPU-0 CHP-0
RUN
M
defines program operation
sets mode for compare address stop
outputs a firmware dump to tape or to magnetic tape
cartridge (for service only)
executes HSA dump (for service only)
(HSA = Hardware/Software Area)
executes functions 1 - 4
Standard processing in SVP mode
E45L01G
ADDRESS COMPARE STOP
ADRS TYPE=>
*1 ABSOLUTE
*2 LOGICAL
ADRS COMP SELECT=>
*1 ANY
*2 OPERAND FETCH(OFETCH)
*3 OPERAND STORE(OSTORE)
*4 INSTRUCTION ADRS(IA)
*5 IA & OFETCH
*6 OFETCH & OSTORE
ADRS SET=> XXXX
=> XXXXXXXX
ADRS COMP MODE=>
*1 RESET
*2 SET
*3 NORMAL
M
FLAG CODE = D9055 7 3 00000I00
[]-[]00
, you can execute various manual
ENTER
U41182-J-Z126-1-74

Advertisement

Table of Contents
loading

This manual is also suitable for:

S120-bS120-eS120-cS120-d