Kohler 5EKD-Low CO Operation page 21

Marine generator sets. controller: advanced digital control ii
Table of Contents

Advertisement

Warnings
Code
Description
Hi CO:
High CO from
sensor
sensor. Fault
code is displayed
if the presence of
CO is detected.
Warning occurs if
the sensor detects
acceptable but
increasing CO
levels.
CO sensr err Faulty CO sensor
Low oil pres
Low oil pressure
Hi eng temp
High engine
temperature
Maint req
Maintenance
required
Figure 2-7 Advanced Digital Control II Warnings
In addition to the fault shutdowns and warnings included
in
Figure 2-6
and
shutdowns/warnings may occur (see Figure 2-8).
Contact an authorized Kohler distributor/dealer for
additional diagnostics.
Text Displayed
Description
Fault Shutdowns:
TPS input hi
Throttle Position Sensor Input High
TPS range hi
Throttle Position Sensor Range High
TPS range lo
Throttle Position Sensor Range Low
TPS input lo
Throttle Position Sensor Input Low
ETC sticking
Electronic Throttle Control Sticking
ETC driver
Electronic Throttle Control Driver Fault
MAP input hi
Map Sensor Input High
MAP input lo
Map Sensor Input Low
Trans hi
XDRP Sensor Input High
Trans lo
XDRP Sensor Input Low
IAT input hi
Intake Air Temp. Input Sensor High
IAT input lo
Intake Air Temp. Input Sensor Low
ECT input hi
Coolant Sensor Input High
O2 input hi
Oxygen Sensor Input High
O2 input lo
Oxygen Sensor Input Low
O2 adapt
O2 Adapt Limit Fault
CAN loss
CAN Receive Message Fault
Overload
Power Limit Shutdown
TP-6591 10/13
Sensing
Active
Mechanism
State
Pulsed signal
10 Hz
Pulsed signal
5 Hz
Digital
Grounded
ECM data
Above setting
Clock
N/A
Figure 2-7,
other
fault
Inhibit
Delay
Default
Time
Time
Setting Check
0 sec
10 sec
N/A
0 sec
10 sec
N/A
30 sec
0 sec
5 psi
30 sec
0 sec
210_ F
0 sec
0 sec
N/A
Warnings:
EST 1 Low
Spark 1 Timing Low
EST 1 High
Spark 1 Timing High
EST 2 Low
Spark 2 Timing Low
EST 2 High
Spark 2 Timing High
Injector
Injector Fault
Oil sens err
Oil Pressure Sensor
ETC spring
Electronic Throttle Control Spring Test Failed
ECT input lo
Coolant Sensor Input Low
O2 sens open
O2 Open Circuit
O2 limit err
O2 Limit Error
Starter
Starter Fault
Overload
Power Limit Warning
Figure 2-8 Fault Shutdowns/Warnings
Ensure windows are open for proper
ventilation.
Operate the blower to expel
dangerous fumes.
Move the vessel away from other
vessels (as another vessel may be the
source for the presence of the CO).
Check the generator exhaust system
(see Section 3.6).
Contact an authorized
distributor/dealer for service.
Replace the CO sensor. Contact an
authorized distributor/dealer for service.
Check for leaks in the lubrication
system.
Check the oil level and add oil if the
level is low.
Check for a low engine coolant level.
Check seawater system for reduced
flow.
NOTE: Allow the generator set to
cool down before checking.
Section 2 Operation
21