Page 2
écrite de Pepperl+Fuchs GmbH. Nous déclinons toute responsabilité concernant les fautes éventuelles d’impression et autres erreurs qui auraient pu intervenir lors du montage de cette brochure.
Mounting and operating instructions Signs and Symbols Warning This symbol signals passages in the manual which must be observed at all times. Non-compliance can cause injuries or material damage. Warning Laser This symbol appears in front of warning passages concerning the danger of laser beams. Information This symbol signals passages with useful information.
4.1 Dimensional drawing Type X(mm) VDM18-100/32/105/122 18,4 VDM18-300/32/105/122 21,5 Illustr. 1 Sensor alignment Position VDM18 so that the distance from the object is within the operating range of the sensor. Screw the VDM18 sensor to the mounting bracket, e.g. type OMH-VDM18 (not included in delivery) or a suitable device. Only use the holes provided in the housing (see dimensioned drawing) for this purpose.
Mounting and operating instructions Electrical installation Turn the sensor connector plug according to the installation position (Illustr. 1) so that the connection cable can be freely connected without being bent. Insert the socket of the connection cable into the VDM18 connector and screw tight. For example, secure the connection cable from sliding with a cable tie.
Mounting and operating instructions Operation and Setting Possible Settings and Operating Modes The VDM18 is ready to operate after applying the operating voltage. However, the following settings can be made if necessary: · Set the switching point or switching window ·...
Page 7
Mounting and operating instructions Make settings 6.4.1 Activating the Set Mode (conf): Press the buttons „S“ and „T“ simultaneously for 3 s (or longer) until the LED BA (green) fl ashes (LED fl ashes when time lock open and Set mode activated). 6.4.2 Setting the Sensor No.
Page 8
Mounting and operating instructions No. LED Description Factory setting Switch operating mode (speed mode / averaging mode) speed mode Press until the „Av“ LED lights up. The operating mode (speed / averaging) is changed by pressing repeatedly. Look at the „ZA“ LED (red). „ZA“ lights = averaging mode is active. „ZA“...
Mounting and operating instructions Optical data (typ.) Operating range VDM18-100 30 ... 100 mm Measuring range VDM18-100 70 mm Operating range VDM18-300 80 ... 300 mm Measuring range VDM18-300 220 mm Resolution* 1 < 0.1% of measuring range Pulsed laser light, red 650 nm, MTBF>50,000h * 2 Light used Size of light spot VDM18-100 1.5 mm x 3 mm at 30 mm / 1.5 mm x 3.25 mm at 100 mm...
Page 10
E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com D O C T-1118 A 19747 3 Subject to modifications 12 / 2 0 07 Copyright PEPPERL+FUCHS • Printed in Germany...
Need help?
Do you have a question about the VDM18-300/32/105/122 and is the answer not in the manual?
Questions and answers