"Service Request" Light Comes On During Operation

DISCONNECT POWER AT CIRCUIT BREAKER.
Check high-limit thermostats
(see Figure 18 on page 35).
High-limit
Yes
thermostats
OK?
Check controller (see Figure 15 on page 32) and
replace as necessary.
P
22
AGE
"Service Request" light comes on during operation.
Turn unit off and check that unit drains fully.
Open door. Turn unit back on and wait 20 minutes.
Is water level
Yes
at normal level
in cavity?
No
Replace high-limit
thermostats
as necessary.
SEZ S
C
ERIES
OUNTERTOP
No
Check for adequate water pressure to unit.
DISCONNECT POWER AT CIRCUIT BREAKER.
Check controller (see Figure 15 on page 32).
Controller OK?
Yes
Check water solenoid (see Figure 16 on page 33).
Water solenoid OK?
Yes
Remove screen from strainer and clean or replace
as necessary. Reassemble, reconnect, and recheck
the steamer. If the Service Request light still comes
on, examine the following for obstructions or
deposits: pressure regulator, solenoid, and check
valve. Clean or replace as necessary.
O
'
M
1183437
PERATOR
S
ANUAL
S
TEAMERS
No
Replace controller.
No
Replace
water solenoid.