Water Solenoid Check - Southbend SEZ/3 Operator's Manual

Super simple steam sez series countertop steamers
Table of Contents

Advertisement

SEZ S
C
ERIES
OUNTERTOP
Figure 16

Water Solenoid Check

1. DISCONNECT
POWER
BREAKER.
2. Remove rear cover.
3. Disconnect water solenoid lead wires from
wires B60 and B61.
4. Place test leads into water solenoid lead
wires as shown.
5. Resistance should be approximately 800
ohms. Replace if necessary.
6. Disconnect water inlet subassembly from
float control box at the compression fitting
closest to the box.
7. Apply of water pressure (approximately 15
psi) to water inlet. Water should not leak out
of the compression fitting.
replace solenoid.
8. Reassemble water inlet, reconnect solenoid
lead wires, and reconnect power to unit.
When power is turned on, the solenoid
should "click." If no click is heard, test for 200
to 240 volts on wires B60 and B61 within four
minutes of turning on power switch. If 200 to
240 volts is present and the solenoid does
not click, replace solenoid.
O
S
TEAMERS
AT
CIRCUIT
If necessary,
'
M
1183437
PERATOR
S
ANUAL
T
ROUBLESHOOTING
P
33
AGE