Excessive Steam Coming from Pressure Relief Vent

Remove control panel, but leave plug connected.
Check controller (see Figure 15 on page 32).
Controller OK?
Yes
Check contactor and
replace as necessary
(see Figure 11 on page
28).
O
S
TEAMERS
Excessive steam coming from pressure relief vent.
DISCONNECT POWER AT CIRCUIT BREAKER.
Check pressure switch for proper operation (see Figure 17 on page 34).
Yes
Pressure switch OK?
No
Replace controller.
'
M
1183437
PERATOR
S
ANUAL
T
ROUBLESHOOTING
No
Replace pressure switch.