Heating Element Resistance Check (at Contactor)

1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove control panel.
3. DO NOT REMOVE HEATING ELEMENT LEAD WIRES FOR THIS TEST.
4. Place test leads between terminals A and C on left side of contactor.
5. Check the resistance and compare to the allowable range in the following table:
Voltage
A-B or B-C
208
10 to 12
220
12 to 13
240
14 to 16
480
55 to 64
6. For three-phase units, check resistance between terminals A and B and between terminals B and
C similarly.
O
S
TEAMERS
Model SEZ/3
Allowable Resistance (Ohms)
Three-Phase
Single-Phase
A-C
14 to 16
15 to 18
18 to 21
73 to 85
29 to 34
'
M
1183437
PERATOR
S
ANUAL
T
ROUBLESHOOTING
C
B
A
Allowable Resistance (Ohms)
Three-Phase
A-C
A-B or B-C
5 to 6
8 to 10
6 to 7
9 to 11
7 to 9
11 to 13
45 to 52
Contactor
(top view)
Model SEZ/5
Single-Phase
A-C
A-C
11 to 13
4 to 5
13 to 15
5 to 6
15 to 17
6 to 7
60 to 70
24 to 28