Siemens SIMATIC FM 453 Getting Started page 5

First steps in commissioning
Hide thumbs Also See for SIMATIC FM 453:

Advertisement

If an error occurs during testing, you can reset by clicking the button
or
DIQ
in the startup window.
You can read the error message number and error message with the menu command
in the overview window.
If you change machine data, you can activate these changes by clicking on the button
ter loading the FM.
Note: For more information regarding startup, please see Section 7 of the Manual.
You can find information on parameterizing the FM 453 in Section 7 of the Manual.
Linking into user program using an example
By installing the configuring package, you have installed the example project "zEn17_02_FM453_Ex".
With the example 1 from this project you can, move the axis of the FM 453 after following the previous
steps.
Do the following:
Close "Parameterize FM 453" , "Properties" and "S7 HW Config".
Confirm the message "Save changes in SIMATIC 400 (1)?" with Yes.
Open the example project zEn17_02_FM453_EX in the SIMATIC Manager with the menu command
File → Open →
Project.
In this example project select the directory "EXAMPLES".
This directory contains:
S a file "Symbols"
S a directory "Blocks"
Select the file "Symbols" and copy it into your project under
Program.
Confirm the message "...Do you want to replace the existing object and all its components?" with Yes.
Open the directory "Blocks" in the example project zEn17_02_FM453_EX and copy all blocks in your
project under
SIMATIC 400 Station → CPUxxx → S7 Program →
The following blocks are in your project:
S FC 0 to FC 3 − technology functions
S FC 100 − basic example for setting the operating mode
S FC 101 to FC 103 − examples 1, 2, 3
S DB 1 − user data block (from UDT 1)
S DB 100 − example data block (DBEX)
S OB 1 − cycle OB
S OB 100 − restart OB
S OB 82 − diagnosis alarm OB
S UDT 1 − user-defined data type
S Variables table VAT1...3
Open "OB100" with a double click.
The LAD / STL / FBD editor will be started.
For the example, enter the call parameter LADDR:=512 in OB 100 in the FC "POS_INIT" under Net-
work 2.
Note: For channel 2 or 3 enter channel no. 2 or 3 in "CH_NO".
Save OB 100 by selecting
Close the Editor.
Select
SIMATIC 400 Station → CPUxxx → S7 Program → Blocks
the S7 blocks (including system data) stored in this directory to your CPU (CPU in STOP state) by
selecting
Target System →
Switch your CPU to the RUN-P state.
File →
Save.
Load.
Restart
or
Ack.
SIMATIC 400 Station → CPUxxx → S7
Blocks.
in the SIMATIC Manager. Load all
(Acknowledge)
Test → Alarms
MD active
af-
− 5 −
-5

Advertisement

loading