Application
Continuous measurement of the dissolved oxygen
concentration plays an important role in monitoring boiler feed
water:
• Trace quantities
Oxygen may only be present in trace quantities. Excessive
concentrations of oxygen can result incorrosion damage in the
circuit.
• Thermal resp. chemical degassing
Boiler feed water is thermally and chemically degassed to
achieve oxygen-free water. This state must be maintained in
service under process conditions.
• Laboratory measurement vs. continuous process monitoring
Spot laboratory measurements to measure oxygen involve a
risk of error due to sampling errors. Continuous measurement
directly in the process eliminates this risk and provides
reliable information about the state of the medium at any
time.
Your benefits
• Maximum measurement accuracy:
– Longterm-stable measurement thanks to potentiostatic
amperometric three-electrode system
– Long maintenance intervals
– Intelligent sensor self monitoring
• Calibration to any transmitter or location and subsequent
installation at measuring point (in digital mode with Liquisys
M COM 223/253) as calibration data is stored in the sensor
• Membrane covered sensor, i.e.:
– high O
selectivity
2
– Minimum maintenance effort
– Minimum calibration effort thanks to simple calibration in
air

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Oxymax W COS71 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Endress+Hauser Oxymax W COS71

  • Page 1 Technical Information Oxymax W COS71 Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement Application Continuous measurement of the dissolved oxygen concentration plays an important role in monitoring boiler feed water: • Trace quantities Oxygen may only be present in trace quantities. Excessive concentrations of oxygen can result incorrosion damage in the circuit.
  • Page 2: Function And System Design

    Oxymax W COS71 Function and system design Measuring principle The oxygen molecules diffused through the membrane are reduced to hydroxide ions (OH-) at the cathode. Silver is oxidized to silver ions (Ag+) at the anode (this forms a silver halogenide layer).
  • Page 3 Oxymax W COS71 Input Measured variable dissolved oxygen [mg/l, ppm, % SAT or hPa] Measuring range with Liquisys M COM223/253-WX/WS: 0.001 to 20.000 mg/l 0.0 to 200.0 % SAT 0 to 400 hPa Wiring Electrical connection Direct connection to the transmitter (field device) Connect the sensor directly to the transmitter (COM253-WX/WS) by using the special measuring cable with SXP plug.
  • Page 4: Performance Characteristics

    Oxymax W COS71 Connection with cable extension To lengthen the sensor connection beyond the length of the fixed cable, you require a junction box VS. Always connect the sensor cable with the SXP plug to the junction box. The cable extension to the transmitter then depends from the transmitter version, i.e. field device or panel mounted device.
  • Page 5: Installation

    Oxymax W COS71 Installation Angle of installation The sensor can be installed up to the horizontal in an assembly, support or a suitable process connection. Other angles are not permissible. Do not install the sensor overhead. a0004087 Angle of installation Permissible installation positions: 0 ...
  • Page 6: Mechanical Construction

    Oxymax W COS71 Mechanical construction Design, dimensions a0004083-en a0004084-en Fixed cable version TOP68 version Weight with cable length 7 m (23 ft): 0.7 kg (1.5 lbs.) with cable length 15 m (49 ft): 1.1 kg (2.4 lbs.) with TOP68 plug-in connection: 0.3 kg (0.66 lbs.)
  • Page 7: Ordering Information

    Oxymax W COS71 Ordering information Product structure Certificate Ex free version Cable length Cable length: 1.5 m (4.9 ft) Cable length: 7 m (23 ft) Cable length: 15 m (49 ft) Without Cable (TOP 68 version only) Special design to customer specifications...
  • Page 8 • field or panel-mounted housing ® • Hart or Profibus available • Ordering acc. to product structure, see Technical Information (TI 199C/07/en) Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com...