Endress+Hauser Deltapilot S DB50 Technical Information

Endress+Hauser Deltapilot S DB50 Technical Information

Hydrostatic level measurement pressure sensor with contite measuring cell
Table of Contents

Advertisement

Technical Information
Deltapilot S DB50/50L/51/52/53
Hydrostatic Level Measurement
Pressure sensor with CONTITE
waterproof, climatic-proofed, long-term stability; for food, fresh
water and wastewater, chemical and pharmaceutical products
TI257P/00/en
71034474
TM
measuring cell;
Application
The devices in the Deltapilot S product family are used
for continuous level measurement in all liquid and paste-
like media. They are used in both the chemical,
pharmaceutical and food industry as well as in the water
and wastewater sector.
Switching units perfectly in line with the application:
• Determine the level, volume, differential pressure,
density and product weight
• Control limit contacts
• Integrate the measuring point in various automation
systems.
Your benefits
• Hermetically sealed CONTITE
– Climatic-proofed and with high long-term stability
– Maximum linearity (better than 0.1 % of the set
measuring range)
– Minimum temperature effects
(better than 0.1%/10 K).
• Compact, rod or cable versions available
• Separate mounting of housing and electronic insert
(IP 68 protection at the measuring point)
• Easy and comfortable operation:
– Onsite with display and operating module
– Operation via communication
• Replaceable electronic inserts:
– 4 to 20 mA HART
– PROFIBUS PA
– FOUNDATION Fieldbus
– Analog output
– PFM
TM
measuring cell:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Deltapilot S DB50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Endress+Hauser Deltapilot S DB50

  • Page 1 Technical Information Deltapilot S DB50/50L/51/52/53 Hydrostatic Level Measurement Pressure sensor with CONTITE measuring cell; waterproof, climatic-proofed, long-term stability; for food, fresh water and wastewater, chemical and pharmaceutical products Application The devices in the Deltapilot S product family are used for continuous level measurement in all liquid and paste- like media.
  • Page 2: Table Of Contents

    ....19 Special measuring cells for substances with hydrogen formation Special measuring cell for acids, alkalis or sea water ..19 Endress+Hauser...
  • Page 3 Installation Drawings/Control Drawings ....59 Overfill protection ........59 Endress+Hauser...
  • Page 4: Function And System Design

    – Stainless steel version (AISI 316L) for hygienic requirements as well as aluminum and polyester housing versions – 3A and EHEDG approval – Maximum flexibility thanks to modular design EExia, FM IS, CSA IS: 0.5 to 100 m (20 to 3937 inch) Endress+Hauser...
  • Page 5 • Special measuring cell with gold-rhodium coating for applications in which severe hydrogen formation can occur (e.g. digested sludge); see also Page 19. • Special measuring cell with gold-platinum coating for acids, alkalis or sea water; see also Page 19. Endress+Hauser...
  • Page 6: Measuring Principle

    Two temperature sensors are arranged between the process diaphragm and measuring element which measure the distribution of temperature in the cell. The electronics can compensate any measuring errors resulting from fluctuations in temperature with these temperature measured values. Endress+Hauser...
  • Page 7 You can determine the differential pressure in tanks with pressure overlay using two Deltapilot S probes. The pressure measured values of the two probes are sent to a signal processing unit such as Endress+Hauser RMA or a PLC. The signal processing unit or PLC determines the difference in pressure and uses this to calculate the level and the density where necessary.
  • Page 8 Deltapilot S and the limit switch. The signal processing unit then calculates the level from the new density and the measured pressure from the Deltapilot S probe. ➁ ➂ Δh ➀ P01-DB5xxxxx-15-xx-xx-xx-006 Level measurement with automatic density correction Deltapilot S Liquiphant Endress+Hauser...
  • Page 9: Communication Protocol

    • 4 to 20 mA with HART communication protocol • PROFIBUS PA – The Endress+Hauser Deltapilot S devices meet the FISCO model requirements. – Due to the low current consumption of 10 ± 1 mA, the following can be operated at one bus segment with installation as per FISCO: –...
  • Page 10: Human Interface

    4 1/2-digit display of measured values and parameters Current matrix position Bar graph of the measured value Operating matrix Operating keys Signal for reporting an error Communication signal, lights up when operating using the handheld terminal or via remote operation Endress+Hauser...
  • Page 11: Operating Elements

    The DAT module can be ordered as a spare part (order number: 542585-0000). However, the measuring cell number must be stated when ordering. Handheld terminals – HART With the handheld terminal Universal-HART-Communicator DXR275 or DXR375, all the parameters can be configured anywhere along the 4 to 20 mA line via menu operation. Endress+Hauser...
  • Page 12: Fieldcare - Hart, Profibus Pa

    Remote operation – An FF configuration program is required to integrate a device with "FOUNDATION Fieldbus signal" into an FF FOUNDATION Fieldbus network or to set the FF-specific parameters. Please contact your local Endress+Hauser Sales Center for more information. Input (measured variable)
  • Page 13: Explanation Of Terms

    Set span This span is based on the zero point. Span based on zero point Nominal value i upper range limit (URL) Nominal measuring range Sensor measuring range Lower range limit Upper range limit Lower range value Upper range value Endress+Hauser...
  • Page 14: Output

    0.204 Hz/mbar 0 to 10000 mbar 0.1 Hz/mbar –900 to 10000 mbar 0.092 Hz/mbar Damping • 0 to 99 s configurable via the FHB20 display and operating module, PC with operating program or handheld terminal • Factory setting: 0 s Endress+Hauser...
  • Page 15: Power Supply

    "PROFIBUS DP/PA: Guidelines for planning and commissioning". FOUNDATION Fieldbus electronics – FEB26 The twin-core cable must be connected to the "FF+" and "FF–" terminal. More information on laying out and grounding the network is provided in Operating Instructions BA013S "FOUNDATION Fieldbus Overview". Endress+Hauser...
  • Page 16: Supply Voltage

    Cable specification 0.1 to 1.2 mA analog • Endress+Hauser recommends using a shielded, three-core instrument cable with max. 25 Ω per core. • Terminals for wire cross-section: 0.08 to 2.5 mm • Endress+Hauser recommends using a shielded, twin-core instrument cable with max. 25 Ω per core.
  • Page 17: Residual Ripple

    • As per DIN 16086 conditions • Calibration temperature: +25°C (+77°F) Position during calibration ➀ DB50(A), DB50L, ➁ DB50S ➁ DB51(A), DB 52(A), ➀ ENDRESS+HAUSER DELTAPILOT S DB53(A) P01-DB5xxxxx-11-xx-xx-xx-009 Zero-point increase 90% of measuring range Long-term stability ±0.1% of URL per 6 months...
  • Page 18: Operating Conditions (Installation)

    • The O-Ring seal in the housing cover and the thread of the aluminum cover are lubricated. If this lubrication has been removed, replace it with silicone grease or graphite paste, for example, so that the cover seals tight. Do not use mineral-oil based greases. These can destroy the O-ring. Endress+Hauser...
  • Page 19: Housing Adapter With Mounting Bracket For Humid, Damp And Difficult-To-Access Mounting Locations

    • To reduce the formation of hydrogen, you should refrain from using galvanized assemblies. Special measuring cell for For acids, alkalis or sea water, Endress+Hauser offers diaphragms with a gold-platinum coating. acids, alkalis or sea water → Order through 50 "Measuring cell version", type Z "Additional specification". In addition, indicate the order number 52009332 for Version 'Z'.
  • Page 20: Operating Conditions (Environment)

    The following electronic inserts are equipped with an surge arrester: – 0.2 to 1.2 mA analog – FEB11P – PFM – FEB17P – 4 to 20 mA HART – FEB22P – PROFIBUS PA – FEB24P Protective diodes: gas tube surge arrester 230 V, nominal discharge current 10 kA Endress+Hauser...
  • Page 21: Operating Conditions (Process)

    Deltapilot S housing versions Aluminum housing Polyester housing Stainless steel housing Dimensions written in italics apply to devices with a cover including a sight glass. Devices with the FHB20 onsite display are always supplied with a cover with a sight glass. Endress+Hauser...
  • Page 22: Process Connections Db50 And Db50A (Compact Version)

    220.2 With a flame barrier Flat 304.5 312.5 204.2 High (with sight glass) 325.5 312.5 231.5 Devices with the FHB20 display and operating module are always supplied with a high cover or with a cover with a sight glass. Endress+Hauser...
  • Page 23 19.1 152.4 AISI 316/ 0.94 6.19 0.06 0.75 316L 228.6 23.9 157.2 19.1 190.5 Combination of AISI 316 for required pressure resistance and AISI 316L for required chemical resistance (dual rated) Weight incl. pipe, housing weight, see Page 32 Endress+Hauser...
  • Page 24 High (with sight glass) 333 + flange 322 + flange 326 + flange thickness b thickness b thickness b Devices with the FHB20 display and operating module are always supplied with a high cover or with a cover with a sight glass. Endress+Hauser...
  • Page 25: Process Connection Db50L And Db50S (Food Version)

    Process connection DB50L/DB50S, version 50: Tri-Clamp ISO 2852 DN 40 – DN 51 (2")/DIN 32676 DN 50, EHEDG, 3A; ≤ 0.8 μm as standard. Lower Material: AISI 316L/1.4435; surface roughness of surfaces in contact with the medium R surface roughness on request. Endress+Hauser...
  • Page 26 Polyester housing Stainless steel [mm] [mm] housing [mm] Without a flame Flat barrier High (with sight glass) Devices with the FHB20 display and operating module are always supplied with a high cover or with a cover with a sight glass. Endress+Hauser...
  • Page 27: Process Connections Db51 And Db51A (Rod/Pipe Version)

    DB51(A), rod version with flange DB51(A), flange without flame barrier DB51(A), flange with flame barrier (flame barrier for use in hazardous areas, Zone 0) For installation height H, see Page 24 → For process connection dimensions, see Page 23 ff. Endress+Hauser...
  • Page 28: Dimensions Of Deltapilot Sdb52 And Db52A (Cable Version)

    For installation height H, see Page 22 Probe length: Without approval, EEx nA II T6: 0.5 to 200 m (20 to 7874 inch) EEx ia IIC T6, FM IS, CSA IS: 0.5 to 100 m (20 to 3937 inch) Endress+Hauser...
  • Page 29 Without approval, EEx nA II T6: 0.5 to 200 m (20 to 7874 inch) EEx ia IIC T6, FM IS, CSA IS: 0.5 to 100 m (20 to 3937 inch) → For process connection dimensions, see Page 23 ff. Endress+Hauser...
  • Page 30: Dimensions Of Deltapilot Sdb53 And Db53A (Suspension Clamp And Mounting Bracket)

    264 mm High (with sight glass) 286 mm 273 mm 280 mm Dimension H Cover Aluminum housing Polyester housing Stainless steel housing Flat 219 mm 227 mm 218 mm High (with sight glass) 240 mm 227 mm 234 mm Endress+Hauser...
  • Page 31: Dimensions Of Connecting Cable With Housing Adapter And Mounting Bracket

    "Additional option" or subsequently as an accessory. → See also Page 19 and Page 56, "Housing adapter with mounting bracket" section. • When using a housing adapter in the EEx ia, FM IS or CSA IS area, the total cable length (connecting cable (L1) + extension cable (L2)) must not exceed 100 m. Endress+Hauser...
  • Page 32: Weight

    DIN 11851 dairy fitting DN 50 incl. nut 1.1 kg Universal process adapter 0.7 kg Universal process adapter with 6 inch extended diaphragm seal 1.5 kg Note! • Total weight of device = weight of housing + weight of process connection DB50L and DB50S Endress+Hauser...
  • Page 33 1.0 kg Note! • Total weight of device = weight of housing + weight of cable x length + weight of mounting bracket + weight of pipe bend + weight of suspension clamp + weight of measuring cell tube Endress+Hauser...
  • Page 34: Material

    – Multi-core cable with steel braiding, PE insulation – Pipe bend: – AISI 316 Ti (1.4571) and AISI 321 (1.4541) – Cable gland: – CuZn nickel-plated – O-ring: NBR – Sealing insert: TPE-V – O-ring: EPDM • Mounting bracket: AISI 304 (1.4301) Endress+Hauser...
  • Page 35: Certificates And Approvals

    Deltapilot S Certificates and approvals CE mark The device meets the legal requirements of the EC directives. Endress+Hauser confirms that the device has been successfully tested by applying the CE mark. Ex approvals All explosion protection data are given in separate documentation which is available upon request. The Ex documentation is supplied as standard with all devices approved for use in explosion hazardous areas.
  • Page 36: Ordering Information

    < 0.1 % of measuring range; FDA compliant < 0.1 % of measuring range; inert oil Additional specification Measuring sensor seal: Viton EPDM Kalrez Sensor welded DB50 Order code →For continuation of ordering information for DB50, see the following page. Endress+Hauser...
  • Page 37 … mm connecting cable with housing adapter, IP 68, separate electronics, max. 20000 mm Basic version, adjusted measuring range 5000 mm connecting cable with housing adapter, IP 68, separate electronics, adjusted measuring range DB50 Complete order code Endress+Hauser...
  • Page 38: Db50L - Compact Version For Hygienic Applications

    < 0.2 % of measuring range; FDA compliant < 0.1 % of measuring range; FDA compliant Measuring sensor seal: Kalrez Viton (only with universal process adapter) Sensor welded DB50L Order code →For continuation of ordering information for DB50L, see the following page. Endress+Hauser...
  • Page 39 … mm connecting cable with housing adapter, IP 68, separate electronics, max. 20000 mm Basic version, adjusted measuring range 5000 mm connecting cable with housing adapter, IP 68, separate electronics, adjusted measuring range DB50L Complete order code Endress+Hauser...
  • Page 40: Db51 - Rod Version

    < 0.1 % of measuring range; FDA compliant < 0.1 % of measuring range; inert oil Additional specification Measuring sensor seal: Viton EPDM Kalrez Welded DB51 Order code →For continuation of ordering information for DB51, see the following page. Endress+Hauser...
  • Page 41 … mm connecting cable with housing adapter, IP 68, separate electronics, max. 20000 mm Basic version, adjusted measuring range 5000 mm connecting cable with housing adapter, IP 68, separate electronics, adjusted measuring range DB51 Complete order code Endress+Hauser...
  • Page 42: Db52 - Cable Version With Process Connection

    < 0.1 % of measuring range; FDA compliant < 0.1 % of measuring range; inert oil Additional specification Measuring sensor seal: Viton EPDM Kalrez Sensor welded DB52 Order code →For continuation of ordering information for DB52, see the following page. Endress+Hauser...
  • Page 43 5000 mm connecting cable with housing adapter, IP 68, separate electronics … mm connecting cable with housing adapter, IP 68, separate electronics, max. 20000 mm Basic version, adjusted measuring range 5000 mm connecting cable with housing adapter, IP 68, separate electronics, adjusted measuring range DB52 Complete order code Endress+Hauser...
  • Page 44: Db53 - Cable Version With Suspension Clamp

    FEB22P, 4 to 20 mA, HART FEB22P, 4 to 20 mA, HART, with FHB20 onsite display FEB24P, PROFIBUS PA W FEB24P, PROFIBUS PA, with FHB20 onsite display DB53 Order code →For continuation of ordering information for DB53, see the following page. Endress+Hauser...
  • Page 45 Stainless steel housing AISI 316L NEMA 4X, thread 1/2 NPT Polyester housing IP 66, thread G 1/2 A Aluminum housing IP 66, thread G 1/2 A Stainless steel housing IP 66, thread G 1/2 A Additional option: Basic version Basic version, adjusted measuring range DB53 Complete order code Endress+Hauser...
  • Page 46: Db50A - Compact Version

    FEB22P, 4 to 20 mA, HART FEB22P, 4 to 20 mA, HART, with FHB20 onsite display FEB24P, PROFIBUS PA W FEB24P, PROFIBUS PA, with FHB20 onsite display DB50A Order code →For continuation of ordering information for DB50A, see the following page. Endress+Hauser...
  • Page 47 200 inch connecting cable with housing adapter, NEMA 6P, separate electronics …inch connecting cable with housing adapter, NEMA 6P, separate electronics, max. 800 inch Basic version, adjusted measuring range 200 inch connecting cable with housing adapter, NEMA 6P, separate electronics, adjusted measuring range DB50A Complete order code Endress+Hauser...
  • Page 48: Db50S - Compact Version For Hygienic Applications

    FEB22P, 4 to 20 mA, HART FEB22P, 4 to 20 mA, HART, with FHB20 onsite display FEB24P, PROFIBUS PA W FEB24P, PROFIBUS PA, with FHB20 onsite display DB50S Order code →For continuation of ordering information for DB50S, see the following page. Endress+Hauser...
  • Page 49 200 inch connecting cable with housing adapter, NEMA 6P, separate electronics …inch connecting cable with housing adapter, NEMA 6P, separate electronics, max. 800 inch Basic version, adjusted measuring range 200 inch connecting cable with housing adapter, NEMA 6P, separate electronics, adjusted measuring range DB50S Complete order code Endress+Hauser...
  • Page 50: Db51A - Rod Version

    FEB22P, 4 to 20 mA, HART FEB22P, 4 to 20 mA, HART, with FHB20 onsite display FEB24P, PROFIBUS PA W FEB24P, PROFIBUS PA, with FHB20 onsite display DB51A Order code →For continuation of ordering information for DB51A, see the following page. Endress+Hauser...
  • Page 51 200 inch connecting cable with housing adapter, NEMA 6P, separate electronics …inch connecting cable with housing adapter, NEMA 6P, separate electronics, max. 800 inch Basic version, adjusted measuring range 200 inch connecting cable with housing adapter, NEMA 6P, separate electronics, adjusted measuring range DB51A Complete order code Endress+Hauser...
  • Page 52: Db52A - Cable Version With Process Connection

    FEB22P, 4 to 20 mA, HART FEB22P, 4 to 20 mA, HART, with FHB20 onsite display FEB24P, PROFIBUS PA W FEB24P, PROFIBUS PA, with FHB20 onsite display DB51A Order code →For continuation of ordering information for DB52A, see the following page. Endress+Hauser...
  • Page 53 200 inch connecting cable with housing adapter, NEMA 6P, separate electronics …inch connecting cable with housing adapter, NEMA 6P, separate electronics, max. 800 inch Basic version, adjusted measuring range 200 inch connecting cable with housing adapter, NEMA 6P, separate electronics, adjusted measuring range DB52A Complete order code Endress+Hauser...
  • Page 54: Db53A - Cable Version With Suspension Clamp

    FEB22P, 4 to 20 mA, HART FEB22P, 4 to 20 mA, HART, with FHB20 onsite display FEB24P, PROFIBUS PA W FEB24P, PROFIBUS PA, with FHB20 onsite display DB53A Order code →For continuation of ordering information for DB53A, see the following page. Endress+Hauser...
  • Page 55 Aluminum housing, IP 66, plug M12x1 AISI 316L housing, IP 66, plug M12x1 Aluminum housing, IP 66, plug 7/8" AISI 316L housing, IP 66, plug 7/8" Additional option: Basic version Basic version, adjusted measuring range DB53A Complete order code Endress+Hauser...
  • Page 56: Accessories

    Suspension clamp for Deltapilot S DB53: • Material: stainless steel AISI 316L (1.4435), clamping jaw: fiberglass reinforced PA (polyamide) • Order number: 52010869 → See also Page 30, "Dimensions of Deltapilot S DB53 and DB53(A) "Suspension clamp and mounting bracket" section. Endress+Hauser...
  • Page 57: Protective Cover

    Protective cover P01-DB5xxxxx-00-xx-xx-xx-001 Protection cover For the aluminum and polyester housing, Endress+Hauser offers protective covers with two cable entries. • Max. ambient temperature: +70°C (+158°F) • Material: polyamide (PA) • Order number for protection cover for devices with a flat cover: 942262-0000 •...
  • Page 58: Welding Neck Adapter For Universal Process Adapter

    ø65 G 1 1/2 P01-PMx4xxxx-06-09-xx-xx-000 Welding neck adapter for flush mounting a Deltapilot S DB50 with thread ISO 228 G 1 1/2 A Order number: 52024469, order number with 3.1 inspection certificate: 52024470 Note! • Endress+Hauser offers a pressure sensor dummy for the welding necks with order numbers 52024469 and 52024470.
  • Page 59: Documentation

    Groups A-D DB51A, DB52A, – 4 to 20 mA HART – Order number: 017054-0000 DB53A – PROFIBUS PA – ZD024F + ZD021F – FOUNDATION – ZD067F + ZD021F Fieldbus Overfill protection • WHG: ZE217F/00/en: HART • WHG: ZE238F/00/en: PROFIBUS PA Endress+Hauser...
  • Page 60 Deltapilot S Deutschland Österreich Schweiz Endress+Hauser Vertrieb Service Technische Büros Endress+Hauser Endress+Hauser Messtechnik Beratung Help-Desk Hamburg Ges.m.b.H. Metso AG GmbH+Co. KG Information Feldservice Hannover Lehnergasse 4 Sternenhofstraße 21 Colmarer Str. 6 Auftrag Ersatzteile/Reparatur Ratingen 1230 Wien 4153 Reinach/BL 1 79576 Weil am Rhein...

Table of Contents