Download Print this page

swissflex uni 14_75RF bridge basic Operating Instructions Manual page 19

Hide thumbs Also See for uni 14_75RF bridge basic:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
Problem
Possible cause
Remote control
No mains supply.
or control system
Manual switch or control system
not working.
defective.
Switched capacitor or mains isolation
blank.
Control systems
Thermoswitch on the transformer
suddenly no
may have been triggered or may be
longer travel /
defective.
move.
Thermal cut-out in the transformer
may have been triggered or may be
defective.
Internal fuse may have been triggered
or may be defective.
No mains supply.
Supply line (mains and / or manual
switch / auxiliary control system) inter-
rupted.
The battery-
Block battery / block batteries flat.
operated electric
reset function
Block battery/batteries not connected.
cannot be acti-
vated.
EN
Technical data
Supply voltage: 110–240 V
Remote control power supply: 3 x AAA Batteries
Power rating motors:
Intermittent operation FROM 2 min / 18 min
Power rating user socket : 850 W
User socket fuse: 5 x 20 mm T 4 A
Thrust motors: 4 x 3000 N
Power supply for emergency lowering: 2 x 9 V block
battery
Solution
Restore mains connection.
Contact your supplier / stockist.
Press the button on the mains isolation plug.
Leave the control system in the rest position for 20-30
minutes.
Contact your supplier / stockist.
Contact your supplier / stockist.
Restore mains connection.
Check the supply line and restore contact if applicable.
Check and replace the block battery / block batteries if
necessary.
Connect the block battery / block batteries.
Operating instructions
19

Advertisement

loading
Need help?

Need help?

Do you have a question about the uni 14_75RF bridge basic and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Uni 22_75rf bridge basicUni 20_75rf basic