Measured variable

Measuring range
(detection range)
Operating frequency

Transmitting power

Switching frequency
Antenna opening angle
(3 dB)

Detectable speed

6

Input

Doppler frequency
With an unobstructed radiation path to the surface of the bulk solids, the maximum range is 20 m
depending on bulk solids (reflection characteristics).
This is reduced if container walls, sight glasses or similar need to be penetrated�
24�15 GHz ± 80 MHz
The power produced by the FTR20 is maximum 100 mW e�i�r�p� (equivalent isotrope radiation
performance)�
• Power density directly in front of the device: Approx� 1 mW/cm
• Power density at a distance of 1 m: Approx� 0�3 µW/cm
The power density is clearly below the recommended limit values of the ICNIRP guidelines
"Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic, and Electromagnetic
Fields (up to 300 GHz)" and thus is completely harmless for humans�
max� 2 Hz
approx� ± 11 °
0�09 ��� 62 m/s
Solimotion FTR20
2
2