L A M P R E P L A C E M E N T
To ensure a proper/safe lamp change, carefully read all the following instructions.
USE ONLY GENUINE ORIGINAL PHILIPS™ LAMPS. OTHER BRAND LAMPS WILL
CAUSE DAMAGE AND WILL VOID FIXTURE WARRANTY!
DISCONNECT THE MAIN POWER SUPPLY BEFORE REPLACING LAMP!
FIXTURE MUST COOL FOR 60 MINUTES BEFORE REPLACING LAMP!
NEVER TOUCH LAMP WITH BARE HANDS, ALWAYS WEAR GLOVES!
OIL FROM HANDS WILL SHORTEN LIFE OF LAMP!
MAKE SURE ALL COVERS/PANELS ARE REPLACED/SECURED BEFORE OPERATING
FIXTURE TO PREVENT ANY RISK AND/OR DAMAGE TO EYE RETINA FROM UV
RADIATION EXPOSIURE!
LAMP PROTECTION CIRCUITRY
The fixture LCD Menu Control Display will indicate the lamp life and related lamp warnings with
each power ON, each lamp strike, and when specific lamp hours are reached. The table below
provides details on each lamp life warning. Due to the extreme heat associated with the lamp
and the nature of the internal optical system, it is IMPERATIVE the lamp is replaced when the
LCD Menu Control Display indicates replacement is needed. This is done to protect the internal
optical system as well as prevent accidental lamp explosion, which could lead to hot glass
particles falling from the fixture.
Total Lamp Hours = X – 20%
LCD display will slowly blink with a YELLOW outline and the following warning for 10 mins:
"LAMP LIFE left "X" hours. Please change lamp soon"
Sending a DMX value of 250-251 in Channel 24 (Standard Mode) or Channel 34 (Extended
Mode) from the lighting controller or pressing the OK button on the fixture control panel
will clear this warning.
Total Lamp Hours = X up to X + 20%
LCD display will slowly blink with a RED outline and the following warning for 10 mins:
"LAMP LIFE exceeded by "X" hours. Please change lamp immediately"
Sending a DMX value of 250-251 in Channel 24 (Standard Mode) or Channel 34 (Extended
Mode) from the lighting controller or pressing the OK button on the fixture control panel
will clear this warning.
Total Lamp Hours = X + 20% and higher
LCD display will slowly blink RED Outline and the following warning:
"Lamp Life "X" hours. Danger of lamp explosion and permanent fixture damage.
Replace lamp immediately! User assumes all risks"
This error can ONLY be cleared when the lamp hours are reset.