Fujitsu ARYG72LHTA Design & Technical Manual page 78

Duct type, indoor/outdoor
Hide thumbs Also See for ARYG72LHTA:
Table of Contents

Advertisement

LED lamp
(1) POWER/MODE
(2) ERROR
(3) PUMP DOWN (L1)
LOW NOISE MODE
(4)
(L2 and L3)
PEAK CUT MODE
(5)
(L4, L5, and L6)
Switch button
SW107
MODE
SW108
SELECT
SW109
ENTER
SW112
EXIT
SW110
PUMP DOWN Starts the pump down operation.
¢ Function setting table
No.
Setting item
Level 1
Low noise
1
mode setting
Level 2
Level 1
Level 2
Peak cut mode
2
setting
Level 3
Level 4
Sign "○": Lights off, "●": Lights on
No.
Setting item
1
Low noise mode setting
2
Peak cut mode setting
• Noise level as low noise mode setting
Level1
Level2
13-1. Local setting switch buttons
Lights on while power on.
Green
Local setting in outdoor unit or error code is displayed with blink.
Red
Blinks during error operation.
Orange Lights on during pump down operation.
Lights on during "Low noise mode" when local setting is activated.
Orange
(Lighting pattern of L2 and L3 indicates low noise level.)
Lights on during "Peak cut mode" when local setting is activated.
Orange
(Lighting pattern of L4, L5, and L6 indicates peak cut level.)
Function or operation method
Switches between "Local setting" and "Error code display".
Switches between the individual "Local settings" and the "Error code displays".
Switches between the individual "Local settings" and the "Error code displays".
Returns to "Operation status display".
PUMP
POWER
DOWN
ERROR
MODE
(L1)
Blink
(9 times)
By using the "Low noise mode", the limit of the noise level will be set to decrease
the noise level. The mode comes in 2 levels which can be set accordingly.
To turn on the mode, use the external input terminal (CN131).
• By using this mode, the cooling/heating performance may decrease.
• Depending on the operating condition, the noise level may not decrease even if
the Low noise mode is on.
The capacity limit can be selected when operating with the "Peak Cut mode." The
operation selection can be done by external input terminal (CN132).
The lower the level, the more the effect of energy saving, but the cooling/heating
performance decreases.
AOYG72LRLA
Cooling
53
51
- 74 -
Function or operation method
LED display
LOW NOISE
(L2)
(L3)
(L4)
Content
Heating
Cooling
53
53
51
51
Factory
PEAK CUT
setting
(L5)
(L6)
Unit: dB (A)
AOYG90LRLA
Heating
55
53
13. Function settings