S P EC IFICATION S ELECTRICAL DATA NOISE LEVEL High TYPE Inverter cool & heat 31 dB INDOOR UNIT ARYG24LMLA Medium 29 dB INDOOR UNIT 27 dB OUTDOOR UNIT AOYG24LALA Quiet COOLING CAPACITY 6.80 kW 25 dB Cooling 52 dB HEATING CAPACITY 8.00 kW...
RE FR IGER A N T S Y S T E M DI AG RA M OUTDOOR UNIT INDOOR UNIT Muffler 4-Way 3-Way valve valve Muffler Heat exch Heat exchanger Accumulator Compressor Expansion 2-Way Strainer Strainer valve valve : THERMISTOR (COMPRESSOR TEP.) : THERMIST : THERMISTOR (DISCHARGE TEP.) : THERMIST...
C I RCU IT D I A GR A M THERMISTOR INDOOR UNIT GRAY REACTOR GRAY ( PIPE TEMP. ) BLACK THERMISTOR BLACK ( ROOM TEMP. ) WHITE CN12 BLACK THERMISTOR ( PIPE TEMP. ) BLACK BROWN THERMISTOR BROWN MAIN PCB ( DISCHARGE TEMP.
IN DO O R P C B CIRCUIT DIAGRAM CONTROL UNIT EZ-01227HSE TERMINAL 15-1 15-2 15-3 15-4 15-5 15-6 2(N) UL1015 UL1015 UL1015 AWG20 AWG20 AWG20 OUTDOOR UNIT BLACK WHITE W101 W102 W105 UL1015 AWG16 GREEN E101 UL1015 POWER SUPPLY PCB AWG16 GREEN E102...
Page 7
INDOOR UNIT MAIN PCB K06AK-120SHSE-C1 R1 - R3 1SS355 10k <1/10W> x 3 I C8 13.5V NJM7812 B03B-PASK-1 DC SUPPLY 1SS355 R4 - R6 1.0k <1/10W> x 3 C8 - C10 0.1 <F> x 3 I C2 0.01 NJM7805 <F> 100/ 6.3V <F>...
Page 8
I C26-14 NORMAL COIL CN108 B2P3-VH-B F101 3.15A 250V LF101 ELF20N018A FH101 FH102 FC51FL x 2 W101 BLACK C105 0.010 W102 <YE> VA101 C104 WHITE 470V 0.47 C106 <TNR> <LE> 0.010 <YE> VA102 SA101 470V RA-362M <TNR> E102 GREEN I C26-10 E101 GREEN CN105...
O UTD OOR P C B C IR CUI T D IA G R A M INVERTER ASSEMBLY EZ-0121EHUE EMI FILTER TO INDOOR UNIT ATFC-25-15-12 W103 UL1015 UL1015 AWG20 AWG14 BLACK BLACK UL1015 F202 AWG14 5A 250V W100 WHITE UL1015 AWG20 UL1015 SERIAL...
Page 10
OUTDOOR UNIT MAIN PCB K06AX-1200HUE-C1 POWER SOURCE REACTOR AC230V 50Hz D100 WHITE R400 - R407 BLACK LL25XB60 0.2 <1W> 1% 0.01 470V <KH> <TNR> D101 <LE> LL25XB60 470V <LE> 0.01 <TNR> ORANGE ZPR0RCH400 <KH> I C103 R126 BAYPASS C C119 100k ORANGE RCH4716-070PF07...
ERROR D ET EC TION Indoor unit lamps Wired OPERATION TIMER ECONOMY remote Description control (green) (orange) (green) INDOOR UNIT Serial communication error and WIRED REMOTE CONTROL Wired remote control communica If you use a wireless remote control, the lamp Check run unfinished on the photo detector unit will output error codes by way of blinking patterns.
INDOOR UNIT Application Q'ty Name and Shape Name and Sha ACCESSOR IES (part number) Hanger Remote For suspending the indoor control cord unit from ceiling (9356563009) Drain hose Screw Insulates the drain hose insulation (M4 x 16) and vinyl hose (313806217708) Cable tie (large) Coupler heat insul...
Page 18
OPTIONAL PARTS When connecting the square duct and round duct, use the optional square flange or round flange and flexible duct. Application Name and Shape Name and Shape (part number) Square flange, UTD-SF045T Wired remote 40 mm control UTY-RNNYM 1065 mm Round flange, UTD-RF204 Simple remote control...
Need help?
Do you have a question about the ARYG24LMLA and is the answer not in the manual?
Questions and answers