Advertisement

Quick Links

User Manual
Thank you for selecting our products. Please read this manual before use.
C2100 TCP-RS485
Converter
KEYKING GROUP

Advertisement

Table of Contents
loading

Summary of Contents for KEYKING C2100

  • Page 1 User Manual Thank you for selecting our products. Please read this manual before use. C2100 TCP-RS485 Converter KEYKING GROUP...
  • Page 2: Table Of Contents

    3.5.4 Restore Factory Defaults ..................13 Chapter 4: Setting Steps ........................14 4.1 Setting a New IP Address for the C2100 ................14 4.2 Setting the Server IP Address .................... 16 4.3 Search for the Controller by the Sphinx4 Software ............17 Chapter 5: Remote Control based on Client ...................
  • Page 3: Chapter 1: Summary

     TCP Server, C2100 will wait for the link command from Host (for example: a PC).  TCP Client, C2100 will look for the Host (for example: a PC), and send link command to the Host. Applications: Access Control, T&A, POS, Car Parking, Power Station, Data Switch.
  • Page 4: Leds And Interface

    C2100 User Manual V 1.01 Keyking Group 1.3 LEDs and Interface Image #1- 1 C2100 Converter Surface 1.3.1 LED for Communications PWR: LED for Power Supply, RX: Receiving Status LED, TX: Transmitting Status LED. 1.3.2 Ethernet Interface RJ45 Cable Data LED...
  • Page 5: Power Supply

    Ethernet LED: When the cable is connected between the C2100 and a Switch HUB or PC, the Ethernet ID will be lit. Data LED: When the cable is connected between the C2100 and a Switch HUB or PC, the Data LED will flash.
  • Page 6: Communication Interface

    C2100 User Manual V 1.01 Keyking Group DIP Switch Default Setting (Default Setting): Switch State Description DIP 1 Configurable, Writeable DIP 2 Normal DIP 3 WDT is enabled DIP 4 Normal Sheet 1-2 DIP Switch Normal Setting (Normal Operating Conditions):...
  • Page 7: Chapter 2: Network Diagrams

    Chapter 2: Network Diagrams 2.1 Network Diagram Image #2-1 C2100 Network Diagram 2.2 Wiring Image #2-2 C2100 wiring diagram with TC3XY Please connect the wires as per the above diagram and below description. “C2100: 485+”----------”TC3XY:485+” “C2100: 485”-----------”TC3XY:485-” Keyking Group Limited Page 6 33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel...
  • Page 8: Cable

    C2100 User Manual V 1.01 Keyking Group 2.2 Cable The cable between the C2100 and PC or Switch HUB can be a crossover or straight through cable. 2.2.1 Cable with Switch HUB (Normal Straight Through Cable) Image #2-3 C2100 Straight through cable for use with Switch or HUB ←...
  • Page 9: Diagram

     The C2100 IP Address, ie 192.168.1.100.  That the current IP of the C2100 converter is in the same subnet as the PC that will be used to undertake the setting procedure, ie 192.168.1.X.  If the current IP of C2100 is unknown, please refer to chapter 4.
  • Page 10 Keyking Group Current IP of C2100 Password Image #3-2 After the password is entered (default password is “keyking” without capital letter), click ”Enter” to go to the screen below. Keyking Group Limited Page 9 33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel...
  • Page 11: Homepage

    Default is 1bit Flow Control: Default is None. Local Telnet Port: The local Port of C2100, default value is 8000 Remote Telnet Port: The Host Port, default value is 8000 Telnet Mode: Work Mode, TCP/IP or Client, default is Client.
  • Page 12: Com Port Parameters

     TCP Server, C2100 will wait for the link command from the Host (for example: a PC).  TCP Client, C2100 will look for the Host (for example: a PC), and send a link command to the Host. “TCP Client” mode use is recommended...
  • Page 13: Network Settings

    Click “Network Settings” in image #3-3, then image #2-5 will appear. 3.5.1 IP Address Selection image #3-5 Address Type: “DHCP/Auto IP”: Dynamic IP, C2100 converter will get an IP by DHCP of router. This mode of operation is not recommended “Static IP”: Fixed IP.
  • Page 14: General Configuration Settings

    Password” to save the configuration. 3.5.3 General Configuration Settings Image #3-7 Module Name: Default value is Keyking Group C2100 Module, this can be modified by the user. UPnP Port number: Default value is 6432. “Update Settings”: After any parameters have been changed, please click “Update Settings”...
  • Page 15: Chapter 4: Setting Steps

    C2100 User Manual V 1.01 Keyking Group Chapter 4: Setting Steps If the IP of the C2100 is not known and the default IP address of 192.168.1.100 is uncertain, follow the steps below: Prior to installation please ensure either one of the following: ...
  • Page 16 C2100 User Manual V 1.01 Keyking Group Image #4-2 4. Type the default password: keyking, and the following home page will appear: Image #4-3 Keyking Group Limited Page 15 33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel Tel: (972) 3-5753606/7 Fax: (972) 3-5753608 Website: www.key-king.com...
  • Page 17: Setting The Server Ip Address

    Switch DIP1 to ON, and DIP2 to OFF. DIP3 and DIP4 should be OFF. Allocate the PC an IP address in the same subnet as the C2100. If the IP address of the C2100 is 192.168.1.100, then the PC IP address should be 192.168.1.X where X equals any number between 2 and 254 except 100 which is the same IP address as the C2100.
  • Page 18: Search For The Controller By The Sphinx4 Software

    C2100 User Manual V 1.01 Keyking Group Type the IP address of the PC as the Host IP (Telnet Server IP), like 192.168.1.4, and click “Apply Changes”. Switch DIP1 to OFF, and DIP2 to OFF. DIP3 and DIP4 should be OFF.
  • Page 19 “Stop” Button. Any controllers which are connected to the C2100 converter should now be found and listed on the right hand side of the above screen. Once all the controller(s) are listed click the “Stop” button. The image below shows a single controller has been found.
  • Page 20 C2100 User Manual V 1.01 Keyking Group Tick the box to select this controller Click “Save” Select the controller to be saved into the database by ticking the box then click the “Save” button. Click “Close”, and the controllers will appear in the next screen.
  • Page 21: Chapter 5: Remote Control Based On Client

    C2100 User Manual V 1.01 Keyking Group Chapter 5: Remote Control based on Client If the C2100 is to be controlled through the internet follow the steps below: Note that the Router 1# must either:  Have a Global fixed IP, like 124.93.56.37 or ...
  • Page 22: Setup C2100 In Lan2

    C2100 User Manual V 1.01 Keyking Group 5.1 Setup C2100 in LAN2 Connect the C2100 to a PC directly and setup all parameters as follows. Allocate the C2100 a fixed IP, like 192.168.1.100, and setup the Gateway to 192.168.1.1. Setup the Telnet Server IP to the Router #1 (eg 124.93.56.37).
  • Page 23: Search For The Controller By The Sphinx4 Software

    C2100 User Manual V 1.01 Keyking Group Once sections 5.1 and 5.2 have been completed then the C2100 will look for the Host server via the internet. 5.3 Search for the Controller by the Sphinx4 Software Run Sphinx4. Click Setup/Hardware/Controller Configuration and the image below will appear.
  • Page 24 C2100 User Manual V 1.01 Keyking Group Any controllers which are connected to the C2100 converter should now be found and listed on the right hand side of the above screen. Once all the controller(s) are listed click the “Stop” button. The image below shows a single controller has been found.
  • Page 25 C2100 User Manual V 1.01 Keyking Group This is the controller The IP address The Mac which connects to the of the C2100 Address of C2100 converter through C2100 the RS485 interface. Done. Keyking Group Limited Page 24 33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel...
  • Page 26: Chapter 6: Remote Control Based On Server

    C2100 User Manual V 1.01 Keyking Group Chapter 6: Remote Control based on Server If the C2100 is to be controlled through the internet follow the steps below: Note that the Router 2# must either:  Have a Global fixed IP, like 121.35.94.126 or ...
  • Page 27: Setup The C2100 In Lan2

    6.2 Map the Port of #2 Router to C2100 On the C2100 location side of the internet, ADSL or a popular internet such as VPN can be used. Even though a fixed IP address for this Router is preferable, this is not mandatory as a dynamic IP address will suffice.
  • Page 28: Adding A Controller In The Sphinx4 Software

    C2100 User Manual V 1.01 Keyking Group Port #8000 cannot be occupied by another system. If port #8000 is in use then use another port like #8001. Save all changes and restart the router.. 6.3 Adding a Controller in the Sphinx4 Software Run Sphinx4.
  • Page 29 Setup the MAC Address of the C2100 IP, eg 00-05-4F-00-01-03 Choose “TCP/IP” option. Setup the IP address of the C2100, 121.35.94.126 Once the above items have been completed then click OK, and the following image will appear. The IP address of...

Table of Contents