Keyking Group
RJ45 Cable: RJ45 socket.
Ethernet LED: When the cable is connected between the C2100 and a Switch HUB or PC,
the Ethernet ID will be lit.
Data LED: When the cable is connected between the C2100 and a Switch HUB or PC, the
Data LED will flash.

1.3.3 Power Supply

DC 9V: the Power Supply should be 7~14VDC with a current capacity exceeding 500ma.

1.3.4 DIP Switch

Switch
State
OFF
DIP 1
ON
OFF
DIP 2
Force the IP of converter to
ON
OFF
DIP 3
ON
Enable WDT, more stable
OFF
DIP 4
ON
Keyking Group Limited
33 Jabotinski St., Twin Tower 1, Ramat Gan, 52511,Israel
Tel: (972) 3-5753606/7 Fax: (972) 3-5753608 Website: www.key-king.com
DIP Switch
Function Description
Write Protect
Configurable, Writeable
Normal
the default IP 10.1.1.10
Disable WDT
Normal
Reset the converter
RS485/422
Image #1-3
Parameters including Password, IP, Host IP
cannot be changed.
All parameters can be changed.
When the IP address of the C2100 is not
known, switch DIP2 to on. The IP address will
default to 10.0.0.10, and the password will
default to "keyking"
Turn DIP4 ON for a second to reset
Sheet 1-1
C2100 User Manual V 1.01
Detail
Normally ON.
Normally OFF