CentriPro 3Ø, 6" - 10",
1.15 S.F. Motors
Service Factor
Amps
19.5
17.0
8.5
6.8
28.5
26.0
13.0
10.0
37.2
33.0
16.5
13.0
53.5
46.0
23.0
19.0
69.5
60.0
30.0
24.0
87.5
76.0
37.0
31.0
104.0
94.0
47.0
36.0
60.0
47.1
79.0
63.0
73.0
90.0
109.0
145.0
180.0
220.0
270.0
5-30 HP, 3Ø, 230 and 460 Motors have adjustable voltage feature,
change voltage plugs to convert from 230V to 460V operation.
Voltage Plug Order No's are: PLUG-230V or PLUG-460V.
— Continued
Locked Rotor
Amps
124
110
55
44
158
144
72
56
236
208
104
82
347
320
160
125
431
392
196
155
578
530
265
213
674
610
305
235
340
272
465
372
435
510
650
795
980
1060
1260
L-L
Resistance
0.618
0.806
3.050
4.792
0.504
0.651
2.430
3.760
0.315
0.448
1.619
2.425
0.213
0.312
1.074
1.657
0.189
0.258
0.861
1.278
0.146
0.210
0.666
0.948
0.119
0.166
0.554
0.838
0.446
0.634
0.388
0.486
0.331
0.278
0.218
0.164
0.132
0.115
0.0929