WARNING!
Open master breaker and disconnect all
leads from starter to avoid damage to
meter or electric shock hazard. Connect
the ohmmeter leads as shown above.
Coil with Ohmmeter
1. Set R x 1000.
2. Connect leads as shown.
3. Reading: Should register some value,
Approx. 200-1000 ohms.
What It Means –
Infinity reading indicates coil is open. Zero
reading indicates coil is shorted. In either case,
the coil should be replaced.
A reading of 200-1000 ohms indicates coil is
ok.
15