FULTON ICS Classic Series Instruction, Operation And Maintenance Manual page 93

Gas fired steam boilers
Table of Contents

Advertisement

Parts
Panel Box Parts
Part No.
Relays
2-40-420
Fulton Pump Relay - 120V
2-40-421
Fulton Burner Relay - 120V
2-40-422
Base for Fulton Pump Relay
2-40-423
Base for Fulton Burner Relay
2-40-405
Fulton Pump Relay 220V
2-40-406
Fulton Burner Relay 220V
2-40-403
IDlDO-120V Relay
2-40-402
IGIDO - 120V Relay (manual reset)
2-40-400
IGlDO-A-120V Relay
2-40-401
ID2DO - 220V Relay
Part No.
Switches
2-45-091
On/Off Switch
2-45-092
Manual Reset Switch
2-45-090
Night Switch for two (2) Pressuretrols
Part No.
Motor Starter Relays (Single Phase)
2-40-200
Motor Starter Relay - 120V - 20 AMP
2-40-202
Motor Starter Relay - 120V - 30 AMP
2-40-201
Motor Starter Relay - 220V - 20 AMP
2-40-203
Motor Starter Relay - 220V - 30 AMP
Part No.
Flame Safeguard Control
2-40-260
RM7895F Programmer
2-40-262
RM7800M Programmer
2-40-272*
Display Module For 7800 Series Controls 60-100
*Standard on 60-100 HP; optional 4-50 HP.
Water Level
Relay
Contactor/
Overload–3 Phase
(Upon Request) or
Starter Relay–1 Phase
For Feed Water
Pump Motor
Flame
Safe Guard/
Burner Control
Low Limit
Pressuretrol
(Optional)
84-G 1/01
HP
4-100
4-100
4-100
4-100
4-100
4-100
4-100
4-100
4-100
4-100
HP
4-100
4-100
4-100
HP
4-50
4-50
4-50
4-50
HP
4-50
60-100
Terminal Block
Part No.
Motor Contactors (Three Phase)
2-40-568
Contactor -AB -100- A09NA3- 220V
2-40-567
Contactor- AB -100- A09ND3-120V
2-40-641
Contactor -AB -100- A12NA3- 220V
2-40-642
Contactor- AB -100- A12ND3-120V
2-40-565
Overload - AB - BSB 16
2-40-657
Overload - AB - BSB 15
2-40-648
Overload - AB - BSB 22
2-40-571
Overload - AB - BSB 30
2-40-575
Overload - AB - BSC 10
2-40-643
Overload - AB - BSC 15
2-40-652
Overload - AB - BSC 24
2-40-572
Overload - AB - BSB 42
2-40-573
Overload - AB - BSB 60
2-40-574
Overload - AB - BSB 80
2-40-566
Overload - AB - BSB 90
Note: Contactor Overload depends on motor h.p. and voltage
Part No.
Pressuretrols
4-40-050
Night Heating Pressuretrol Set Up
2-40-227
Pressuretrol L404A - 2-15 PSI
2-40-228
Pressuretrol L404A - 5-50 PSI
2-40-229
Pressuretrol L404A - 10-150 PSI
2-40-230
Pressuretrol L404A - 20-300 PSI
2-40-231
Pressuretrol L404C - 2-15 PSI
2-40-232
Pressuretrol L404C- 5-50 PSI
2-40-233
Pressuretrol L404C - 10-150 PSI
2-40-234
Pressuretrol L404C - 20-300 PSI
Note: Correct pressuretrol is based on boiler trim pressure.
Low Water
Safety Relays
Operating Pressuretrol
HP
4-60
4-60
80-100
80-100
HP
4-100
4-100
4-100
4-100
4-100
4-100
4-100
4-100
4-100
Low Water
Manual
Reset Switch
4-50 HP:
1 Phase Motor
Starter Standard
60 HP:
3 Phase Contactor/
Overload Standard
3 Phase Available
On 4-50 HP As Option
Power
On/Off Switch
High Limit
Pressuretrol
With
Manual Reset

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents