Location and Mounting Continued:
Figure 2–1 illustrates chassis installation.
To install the RCP–48X chassis follow these steps:

2.4 Polling Address

For the controller to identify a particular control panel, a specific device
number or polling address must be assigned to each panel. Valid polling
addresses are in the range of 1 to 128. Systems requiring more than 128
panels are possible with enhanced controllers, refer to your Pesa Sales
Representative for details. The appropriate binary number is entered into
the control panel by setting a 10-position DIP switch to the binary number.
The DIP switch is located on the remote CPU board and is accessible
from the rear of the unit. The panel address is normally assigned and
entered at the factory if the panel is purchased as part of a system and a
design guide has been completed by the user. If the panel is purchased
separately, the user may be required to set the panel address.
Example: To select polling address 21, set switches 6, 8, and 10 in the
"ON" or "1" position. See Figure 2–2.
2
INSTALLATION
page 2.2
Installation
1. Align the chassis with the slotted opening in the rack.
2. Install the bottom screws first.
3. Install the two top screws
4. Tighten all four screws securely.
Figure 2–1 RCP–48X Chassis Installation