Table 7: Set point adjustment · Dimension x
Set point range
8 to 16 bar
15 to 25
10 bar
x = 89 mm
12 bar
x = 97 mm
14 bar
x =104 mm x = 133 mm x = 188 mm
4.5 to 10 bar
5.9 bar
x = 85 mm
7.3 bar
x = 93 mm
8.6 bar
x = 101 mm x = 123 mm x = 192 mm
2 to 5 bar
2.8 bar
x = 83 mm
3.5 bar
x = 92 mm
4.3 bar
x = 100 mm x = 127 mm x = 190 mm
0.8 to 2.5 bar
1.2 bar
x = 79 mm
1.7 bar
x = 89 mm
2.1 bar
x = 99 mm
0.2 to 1.2 bar
0.45 bar
x = 71 mm
0.70 bar
x = 83 mm
1.0 bar
x = 95 mm
0.1 to 0.6 bar
0.23 bar
x = 71 mm
0.35 bar
x = 83 mm
0.48 bar
x = 95 mm
0.05 to 0.25 bar
0.10 bar
x = 70 mm
0.15 bar
x = 81 mm
0.20 bar
x = 91 mm
EB 2517 EN
Valve size DN
32 to 50
65 to 100
x = 111 mm x = 153 mm
x = 122 mm x = 170 mm
x = 105 mm x = 151 mm
x = 117 mm x = 172 mm
x = 102 mm x = 146 mm
x = 115 mm x = 168 mm
x = 97 mm
x = 137 mm
x = 111 mm x = 162 mm
x = 126 mm x = 187 mm
x = 86 mm
x = 118 mm
x = 103 mm x = 147 mm
x = 120 mm x = 177 mm
x = 86 mm
x = 118 mm
x = 103 mm x = 147 mm
x = 120 mm x = 177 mm
x = 85 mm
x = 112 mm
x = 100 mm x = 136 mm
x = 115 mm x = 159 mm

7 Servicing

The regulator does not require any mainte-
nance. Nevertheless, it is subject to natural
wear, particularly at the seat, plug and oper-
ating diaphragm/bellows. Depending on the
operating conditions, check the regulator at
regular intervals to avoid possible malfunc-
tions.
We recommend removing the regulator from
the pipeline before performing any mainte-
nance or service work.
DANGER
!
Risk of bursting in pressure equipment.
Regulators and pipelines are pressure equip-
ment. Improper opening can lead to bursting
of the regulator.
− Before starting any work on the regulator,
depressurize all plant sections concerned
as well as the regulator.
− Disconnect the control line.
− Drain the process medium from all the
plant sections concerned as well as the
regulator.
− Wear personal protective equipment.
WARNING
!
Risk of personal injury due to residual pro-
cess medium in the regulator.
While working on the regulator, residual
process medium can escape and, depending
on its properties, may lead to personal in-
jury, e.g. (chemical) burns.
Wear protective clothing, safety gloves and
eyewear.