Perenio PECLS01 Installation And Operation Manual

Perenio PECLS01 Installation And Operation Manual

Leak sensor
Hide thumbs Also See for PECLS01:

Advertisement

Quick Links

Installation and Operation Manual
for Perenio® PECLS01
Leak Sensor
August, 2019

Advertisement

Table of Contents
loading

Summary of Contents for Perenio PECLS01

  • Page 1 Installation and Operation Manual for Perenio® PECLS01 Leak Sensor August, 2019...
  • Page 3: Introduction

    Copyright of ©Perenio IoT spol s r.o. All rights reserved. The Perenio® trademark is owned by Perenio IoT spol s r.o. (hereinafter referred to as the Perenio IoT). All other similar trademarks and names, as well as logos and other symbols are the property of their respective owners*.
  • Page 4: Responsibility And Technical Support

    Perenio IoT reserves the right to modify the device and make corrections or changes to this document without prior notice of the User, and shall not be responsible for any...
  • Page 5: Conformance To Standards

    Details on available Certificates are specified in Section 6 of the present document. For copies of Certificates and Reports, please visit a corresponding Section at perenio.com. ©Perenio IoT spol s r.o. All Rights Reserved Doc Version: 2.1.0 Page 5 of 28...
  • Page 6: Table Of Contents

    1.3 Scope of Delivery ................. 11 1.4 Packaging and Labelling ................ 12 1.5 Safe Operation Rules ................12 1.6 Standalone Operation of Perenio® Sensors ..........12 2 Installation and Setup ................13 2.1 First Installation and Configuration ............13 2.2 Leak Sensor Tightness ................17 2.3 Changing the Room or Location for the Sensor .........
  • Page 7 A. SWITCHING ON AND INSTALLATION OF THE LEAK SENSOR ......14 B. LOGIN TO THE EXISTING USER ACCOUNT ............14 C. CONNECTION TO THE CONTROL GATEWAY ...........15 ©Perenio IoT spol s r.o. All Rights Reserved Doc Version: 2.1.0 Page 7 of 28...
  • Page 8: General Description And Specifications

    1 General Description and Specifications 1.1 General Purpose The Perenio® PECLS01 Leak Sensor is a device intended to alert users in the case of flood in the room. This device is used as part of the Perenio Smart Building Management System and is suitable for detection of leakage of water and other liquids in the place of its installation.
  • Page 9: Figure 2 - Leak Sensor Buttons And Indicators

    Client or caused to their estates, personal property and/or other products, devices, personal data and privacy. ©Perenio IoT spol s r.o. All Rights Reserved Doc Version: 2.1.0 Page 9 of 28...
  • Page 10: Technical Specification

    On a horizontal surface (for indoor installation). The outdoor installation is possible in the case Installation requirements to the operating temperature and humidity are respected. Doc Version: 2.1.0 ©Perenio IoT spol s r.o. All Rights Reserved Page 10 of 28...
  • Page 11: Scope Of Delivery

    24 months Certification CE, EAC, RoHS, UA.TR 1.3 Scope of Delivery The following items and accessories are supplied within the Perenio® PECLS01 Leak Sensor package: 1. PECLS01 Leak sensor (1 pc.) 2. Battery (CR123A) (1 pc.) 3. Quick Start Guide (1 pc.) 4.
  • Page 12: Packaging And Labelling

    PECLS01 Leak Sensor 1.4 Packaging and Labelling The Perenio® PECLS01 Leak Sensor is supplied in an individual blister package of 171 x 126 x 27 mm (L x W x H) containing the full name and marking of the device, the list of accessories provided and basic technical specifications thereof, as well as the date of manufacture and information about the Manufacturer of devices.
  • Page 13: Installation And Setup

    Smart Mobile App, it is necessary to perform the following steps: 1. Unpack the Sensor and switch it on (See par. A below). 2. Login in to the Perenio Smart Building Management System User Account (See par. B below). 3. Connect the Leak Sensor to the Control Gateway (See par. C below).
  • Page 14: A. Switching On And Installation Of The Leak Sensor

    5. Install the Sensor in the selected room. SWITCHING ON AND INSTALLATION OF THE LEAK SENSOR To install the Perenio® PECLS01 Leak Sensor, follow steps below: 1. Unpack the device. 2. Select suitable installation area near a potential source of flood (water valve, washing machine, radiators, etc.).
  • Page 15: C. Connection To The Control Gateway

    Control Gateways activated in the User Account). NOTE. The Control Gateway must be connected to the mains and the Internet, as well as activated in the Perenio Smart App. Start searching for Sensors; d. If the LED flashes slowly after the first power on of...
  • Page 16 PECLS01 Leak Sensor The entire process of the Sensor connection in the Mobile App is shown below. – Add new device (Sensor) procedure Figure 5 Doc Version: 2.1.0 ©Perenio IoT spol s r.o. All Rights Reserved Page 16 of 28...
  • Page 17: Leak Sensor Tightness

    Make sure that the Sensor is at an allowable distance from the CG; c. Install the Sensor in a new room; d. Change the Room in Sensor settings in the User Account. ©Perenio IoT spol s r.o. All Rights Reserved Doc Version: 2.1.0 Page 17 of 28...
  • Page 18: History And Push-Notifications

    PECLS01 Leak Sensor 2. Change the room/location (Connection to another CG is required) as follows: a. Sign in to the Perenio Smart app and select the Location where the Sensor is activated; b. In the ‘Devices’ tab, select the required Sensor from the list and click on icon (Settings);...
  • Page 19: Battery Replacement

    Gateway firmware update process, as well as low battery notifications and changes of the Armed/Disarmed mode for the Location. Standard events. Various news and other information from Perenio IoT, as well as alerts from both the Door&Window Sensor and the Motion Sensor when in the Disarmed mode.
  • Page 20: Maintenance And Repair

     Repair mechanical damages to devices (in Service Centers). The Perenio® PECLS01 Leak Sensor repairs shall be carried out in Service Centers, because casings will have to be opened in the case of any element failure. In the case of warranty repairs or replacement, the User shall provide the Seller with the sales receipt and the purchased device.
  • Page 21: Warranty Obligations

    The Manufacturer shall guarantee that all materials, components and assemblies of Perenio® devices are free from defects under normal operation within the warranty period. The limited warranty shall be applied to the first End Customer of Perenio® devices only and cannot be transferred to a subsequent customer.
  • Page 22 Perenio® PECLS01 Leak Sensor LIMITATION OF LIABILITY Perenio® devices SHALL NOT BE SUBJECT TO a free warranty service in the case of identification of at least one of the following damages or defects:  Any damage caused by force majeure, accidents, and willful or careless acts (omissions) of the Customer or third parties;...
  • Page 23 ©Perenio IoT spol s r.o. All Rights Reserved Doc Version: 2.1.0 Page 23 of 28...
  • Page 24: Storage, Transportation And Disposal Of Devices

    PECLS01 Leak Sensor 5 Storage, Transportation and Disposal of Devices The Perenio® PECLS01 Leak Sensor may be shipped by any kind of covered vehicles (by rail, or road or in sealed heated airplane compartments, etc.) in accordance with the requirements of current regulatory documents applicable to fragile goods sensitive to moisture.
  • Page 25: Other Information

    ASBIS POLAND Sp. z o.o. Address Ul. Szyszkowa 43, 02-285 Warszawa Quality Claims Acceptance and Warranty Service Company Croatia Name ASBISc-CR d.o.o. Address Slavonska avenija 24/6, 10000 Zagreb, RH ©Perenio IoT spol s r.o. All Rights Reserved Doc Version: 2.1.0 Page 25 of 28...
  • Page 26 Radio Test Report #STS183222W01 as of March 31, 2018; Radio Test Report #STS183222W02 as of March 31, 2018. Addresses of Service Centers are available at perenio.com in the ‘Support’ Section. Doc Version: 2.1.0 ©Perenio IoT spol s r.o. All Rights Reserved Page 26 of 28...
  • Page 27: Troubleshooting

    PECLS01 Leak Sensor 7 Troubleshooting Table 2 below shows typical errors and problems that may occur in the process of connection and configuration of the Perenio® PECLS01 Leak Sensor . Table 2 – Typical Errors and Troubleshooting Methods Item Problem...
  • Page 28: Glossary

    General term which means a building or a structure in which Perenio® Cameras, Control Gateways and/or Sensors are installed Perenio Smart Software developed by Perenio IoT for remote control of wireless Cameras from smartphones ZigBee A network protocol designed for secure transmission of data...

Table of Contents